4.
Center the Gill WindSonic over the three threaded screw holes on the
mounting shaft and screw it in place using the three Phillips screws taken
off the shaft in step 1.
5.
Slide the shaft and sensor back through the U-bolt. Align the sensor with
north by pointing the small colored dot on outer edge of the bottom of the
sensor so it faces true north. Space the sensor about 25.4 cm (10 in) above
the crossarm and tighten down the U-bolt.
2.4.6 Rain Gage
For accurate measurements, the rain gage needs to be installed so it is
horizontally level. A bubble level is situated on the bottom of the inside of the
rain gage. To see the bubble level, pull the gold funnel up and off of the top of
the rain gage. Remove the rubber band holding the tipping mechanism in
place. The rain gage bubble level mounted on the tipping mechanism shows
how vertical the pole was installed. Adjust the bolts at the bottom of the pole
as needed to get the bubble level centered. Put the gold funnel back on the top
of the rain gage after leveling has been completed.
FIGURE 2-18. Remove Rubber Band from Tipping Mechanism
26
Содержание T107
Страница 2: ......
Страница 3: ......
Страница 49: ...T107 Weather Station FIGURE 2 31 Slide Antenna Bracket U Bolt around Back of the Pole 41...
Страница 75: ...T107 Weather Station FIGURE 4 7 Schematic of TE525 ET Rain Sensor and Connector Rain Precip Rain Precip 67...
Страница 78: ...T107 Weather Station 70...
Страница 82: ...Appendix B PS24 24 Ahr Power Supply and 10 x 12 inch Enclosure FIGURE B 2 24 Ahr Battery and Battery Cable B 2...
Страница 83: ...Appendix B PS24 24 Ahr Power Supply and 10 x 12 inch Enclosure FIGURE B 3 Enclosure Supply Kit B 3...
Страница 93: ...Appendix C Exploded Views C 1 Enclosure C 1...
Страница 94: ...Appendix C Exploded Views C 2 Crossarm C 2...
Страница 102: ...Appendix D Default Programs D 8...
Страница 105: ......