![background image](http://html1.mh-extra.com/html/campbell/rwis-stations/rwis-stations_instruction-manual_489457007.webp)
RWIS Stations
3
Loggermap
diff
channel
se
channel
sensor/color
function
12v/color
AG/color
G/color
1
1H
humidity
2L
Air temp
2
3H
open option(oo)
4L
wind direction
3
5H
solrad
6L
solrad
4
7H
sub surface
8L
sub surface
5
9H
sub surface
10L
sub surface
6
11H
rain y/n(oo)*
12L
rainy/n(oo)*
p1
wind speed
p2
tipping bucket
e1
e2
sub surface
e3
wind direction
c1
sdm-sio4
c2
sdm-sio4
c3
sdm-sio4
c4
c5
c6
c7
c8
snow depth
Logger Setup
The CR10X-2M *D and *A menus set the logger for image collection and pb
operation.
*D15 location 1 is the pakbus address and is set to 1
fill in the remainder of the table with values of 4
*D16 location is the amount of memory to set aside for the image in the logger
and is set to 6
*D18 location is the beacon and is set to 60
*D19 location 01 is set to 17 with nothing after
*A location 6 is set to 3000 for the text values that ess1204 requires