RF407-Series Spread Spectrum Radio
2
•
Upon receipt of the RF407-series radio, inspect the packaging and contents
for damage. File damage claims with the shipping company. Contact
Campbell Scientific to facilitate repair or replacement.
•
Immediately check package contents against shipping documentation.
Thoroughly check all packaging material for product that may be trapped.
Contact Campbell Scientific immediately about any discrepancies. Model
numbers are found on each product. On cables, the model number is often
found at the connection end of the cable.
4. QuickStart
Out of the box, the radio is configured for use with a datalogger connecting via
CS I/O and using CS I/O SDC address 7.
4.1 Remote Station Radio
Using the supplied SC12 serial cable, connect the radio’s
CS I/O
port to the
CS I/O
port of the datalogger.
4.2 Base Station Radio
You will need to connect the radio to your PC and use
Device Configuration
Utility
(
DevConfig
) to change the radio’s
Active Interface
to
USB
. To learn
more about connecting with
DevConfig
(p. 10)
. Using
DevConfig
, set the radio’s
Active Interface
setting to
USB
. The
Power Mode
setting should match that of the device you are connecting to.
Apply
the
change(s), close
DevConfig
, and leave the radio connected to the PC via USB.
4.3
LoggerNet
Setup
The next step is to run
LoggerNet
and configure it to connect to the datalogger
via the radio link.
1.
From the EZ View of the
LoggerNet Setup
screen, press
Add
, select your
datalogger type, enter a name for your datalogger, and press
Next
.
2.
Under
Connection Type
, select
Direct Connect
. Press
Next
.
3.
Under
COM Port Selection
, select the port designated as
RF407-Series
.
4.
Under
Datalogger Settings
, select a
Baud Rate
of
115200
, enter the
PakBus Address
of the datalogger, and set
Extra Response Time
to
1
second
. Press
Next
.
5.
Under
Datalogger Settings – Security
, enter any security codes that have
been previously configured in the datalogger. Press
Next
.
6.
Review the
Communication Setup Summary
and verify that all settings
are correct. Press
Next
.
7.
On the
Communication Test
screen, select
Yes
and press
Next
to verify
communication with the datalogger. If unable to communicate, press the
Previous
button and review your settings. Once you have successfully
communicated with your datalogger, press the
Finish
button.
8.
You are now ready to connect to your datalogger using the
LoggerNet
Connect
screen.