Appendix C. EasyFlux
®
DL CR6KH20
C-30
TABLE C-22. Data Fields in the Flux_Notes Output Table
Data Field Name
Units
Description
Data Field
Included
W_SIGMA
m·s
-1
Standard deviation of vertical wind
after coordinate rotations
Always
UV_cov
m·s
-1
Covariance of streamwise and
crosswind after coordinate rotations
Always
UW_cov
m·s
-1
Covariance of streamwise and
crosswind after coordinate rotations
Always
VW_cov
m·s
-1
Covariance of crosswind and vertical
wind after coordinate rotations
Always
UT_SONIC_Cov
m·°C·s
-1
Covariance of streamwise wind and
sonic temperature after coordinate
rotations
Always
VT_SONIC_Cov
m·°C·s
-1
Covariance of crosswind and sonic
temperature after coordinate rotations
Always
WT_SONIC_Cov
m·°C·s
-1
Covariance of vertical wind (after
coordinate rotations) and sonic
temperature
Always
UW_Cov_fc
m
2
·s
-2
Covariance of streamwise and vertical
wind after coordinate rotations and
frequency corrections
Always
VW_Cov_fc
m
2
·s
-2
Covariance of cross and vertical wind
after coordinate rotations and frequency
corrections
Always
WT_SONIC_Cov_fc
m·°C·s
-1
Covariance of vertical wind and sonic
temperature after coordinate rotations
and frequency corrections
Always
WT_SONIC_Cov_fc_SND
m·°C·s
-1
Covariance of vertical wind and sonic
temperature after coordinate rotations,
frequency corrections, and SND
correction
Always
sonic_samples
count
Number of raw sonic samples in
averaging period without diagnostic
flags
Always
no_sonic_head_Tot
count
Number of sonic samples where no
sonic head was detected
Always
no_new_sonic_data_Tot
count
Number of scans where no sonic data
were received
Always
sonic_amp_l_f_Tot
count
Number of sonic samples with
amplitude low diagnostic flag
Always
sonic_amp_h_f_Tot
count
Number of sonic samples with
amplitude high diagnostic flag
Always
sonic_sig_lck_f_Tot
count
Number of sonic samples with signal
lock diagnostic flag
Always
sonic_del_T_f_Tot
count
Number of sonic samples with delta
temp diagnostic flag
Always