EasyAG
®
Soil Water Content Profile Probes
8
‘Load Measurement Failure Errors
If ES1_SF(1) = NAN Then ES1_SF(1) = -99999
‘If probe fails (NAN at first sensor)
For X = 1 to 8 step 1
‘Load
-99999 to all sensors
If
ES1_SF(1)
<
-9999
Then
ES1_SF(X)
=
-99999
ES1_WC(X)
=
-99999
ES1_VIC(X)
=
-99999
Else
‘...OR...
If
ES1_SF(X)
<
-999
Then
‘If a
WC sensor fails (indicated by
-1000)
ES1_WC(X)
=
-99999
‘Load NAN for water content
Else
‘...OR...
ES1_WC(X)
=
((ES1_SF(X)
-
c)/a)^(1/b)
‘apply calibration
EndIf
EndIf
Next X
‘Measure rain
PulseCount
(Rain_mm,1,2,2,0,.01,0)
‘Input irrigation events manually in Irrimax, 0 must be written to data file
Irrig_mm
=
0
‘Output Data to Storage
CallTable
ES1_SF
‘Store Scaled Frequency and VIC Data with Rain and Irrigation
‘for Irrimax Software
CallTable
ES1_WC
‘
Store Water Content Data
‘Next Scan
Next
Scan
‘End Program
EndProg
Содержание EasyAG SDI-12
Страница 2: ......
Страница 3: ......
Страница 26: ...Appendix A Normalization and Function Test A 6 ...
Страница 40: ...Appendix B Tube Installation B 14 ...
Страница 42: ...Appendix C Site Selection C 2 ...
Страница 44: ...Appendix D SDI 12 Commands D 2 ...