EasyAG
®
Soil Water Content Profile Probes
6
8.2 Cable
Installation
Securely tighten the gland nut through which the cable passes into the probe
cap. Inject a small amount of silicon sealant into the sensor end of the cable to
ensure that water or water vapor will not pass into the probe.
9. Datalogger
Programming
Example program corresponds to setup example in Appendix A.
Sample CR1000 Program
Shaded portions of program can be omitted if TriSCAN sensors are not used.
‘CR1000 Data
logger
‘Program Author: Campbell Scientific, Inc.
‘Date: 04
-12-06
‘Description:
Program measures 1 EnviroSMART / TriSCAN probe with 8 sensors or 1 EasyAG
‘
TriSCAN probe with 4 sensors. -1000 is loaded as the "measurement" for
‘
non-existant
sensors.
Program
measures scaled frequencies, calculates
‘
water
contents,
and
stores
scaled frequencies, water contents, and
‘
volumetric ion contents separately. Scaled frequencies are stored with an
‘
"array identifier" leading 8 data values per record followed by 8 VIC per
‘
record, with the record ending with zero rain and irrigation values for
‘
compatibility
with
DBLOAD & Irrimax software.
‘Assumptions:
EnviroSMART
or
EasyAG
probe
SDI-12 interface is configured to output
‘
scaled
frequencies
‘Wiring:
EnviroSMART / EasyAG 12 Volts (Pin 1) --------- CR1000 12 V
‘
EnviroSMART / EasyAG Ground (Pin 2) -------- CR1000 Ground
‘
EnviroSMART / EasyAG Signal (Pin 3)---------- C7
‘
Rain
Gage
Pulse
Out
--------------------------------
CR1000
P2
‘
Rain
Gage
Ground
-----------------------------------
CR1000
Ground
‘Program
Declarations
‘Public (Displayed) Variables
Public
ES1_ID(1)
Public
ES1_SF(8)
Public
ES1_WC(8)
Public
ES1_VIC(8)
Public
Rain_mm
Public
Irrig_mm
‘EasyAG / EnviroSMART Scale Frequency to Water Content Calibration Co
-efficients
Const
a
=
.1957
Const
b
=
.404
Const
c
=
.02852
Содержание EasyAG SDI-12