![Campbell CS125 Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/campbell/cs125/cs125_instruction-manual_3803392041.webp)
User Guide
31
SET transmitted data
Example
Description
0x02
(1)
STX ^ B
(2)
SET
SET
:
Delimiting character
Current Sensor ID
:
Delimiting character
Sensor ID (may be a new ID)
User Alarm 1 Set
User Alarm 1 Active
User Alarm 1 Distance
User Alarm 2 Set
User Alarm 2 Active
User Alarm 2 Distance
Serial Baud Rate
Sensor serial number (read only)
Visibility Units
Message interval
Polling Or Continuous modes
Message Format
RS232 or RS485 serial communications enabled
Averaging Period
Sample timing
Dew heater override
Hood heater override
Dirty window compensation
CRC checking on received commands
Sensor power down voltage
Relative humidity threshold
:
Delimiting character
XXXX
Checksum (use the valid CCITT checksum)
:
Delimiting character
0x03
(1)
ETX ^ C
(2)
0x0D
(1)
Carriage return
0x0A
Line feed
(1)
These values are shown in hexadecimal format not ASCII.
(2) As entered on a keypad.
14.1.1 Example of a SET Command
14.2 The SETNC Command
The format of the SETNC command is nearly exactly the same as the SET
command. The only functional difference is that the SETNC command does not
commit the values set into flash memory. This means that the next time the
CS125 is power cycled it will revert back to its previous settings. This command
SET:0:0 1 1 1000 1 0 15000 2 0 M 60 1 2 0 1 1 0 0 0 1 7 80 :68A3: