![Campbell CS125 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/campbell/cs125/cs125_instruction-manual_3803392027.webp)
User Guide
17
Figure 9-2. Connection for an external CS215 temperature and RH sensor
connected to a CS125
Internal switch functions
Switch number
Function
4
Reserved for future use
3
When switched to the ON position this
switch temporarily sets the CS125
communications port to a default RS232
communication state (38400 bps). This is
useful during field tests or maintenance
when the CS125 has been remotely
configured for RS485 mode or a baud rate
your PC does not support. This change is
temporary and will not be stored to flash.
When switched to the ON position and the
CS125 is power cycled this switch
temporarily sets the CS125
communications port to a default RS232
communication state at 38400 baud. This is
useful during field tests or maintenance
when the CS125 has been remotely
configured for RS485 mode or a baud rate
your PC does not support. This change is
temporary and will not be stored to flash.
However, if the menu system is accessed
and a ‘Save and exit’ command is
performed these new data rate settings will
be committed to flash.