Section 3. Programming
these tables, once space for the fixed-size tables has been allocated. The
datalogger will attempt to size the tables so that both of them will be full at the
same time.
PROGRAM
'CR1000
Public temp
Public batt
DataTable (Table1,1,-1)
CardOut
(1,1000)
Sample(1,temp,IEEE4)
EndTable
DataTable (Table2,1,-1)
CardOut
(1,1000)
Sample(1,batt,IEEE4)
EndTable
DataTable (Table3,1,1000)
DataInterval(0,5,sec,4)
CardOut (0 ,-1)
Maximum
(1,temp,FP2,False,False)
Minimum (1,temp,FP2,False,False)
EndTable
DataTable (Table4,1,1000)
DataInterval(0,5,sec,4)
CardOut (0 ,-1)
Maximum
(1batt,FP2,False,False)
Minimum (1,batt,FP2,False,False)
EndTable
BeginProg
Scan(1,SEC,3,0)
PanelTemp(temp,250)
Battery(Batt)
CallTable
Table1
CallTable
Table2
CallTable
Table3
CallTable
Table4
NextScan
EndProg
3-3