Campbell CCFC Field Camera Скачать руководство пользователя страница 102

CCFC Field Camera 

 

88 

 

12.8.5.4

 

Users 

The  first  user  added  will  always  have  admin 
permissions. 

Users 

allows users, with various access levels, to be added to the 

camera. 

Users 

enables a security login feature, which requires a 

user name and password authentication. Without this activated, 
the camera is open to the Internet. A total of 10 users can be 
added to the CCFC. 

By default, cameras are shipped with the security authentication 
disabled. When 

Authentication

 is set to 

Enable

, users will be 

prompted for a 

User

 

Name

 and 

Password

 before access is given. 

Ensure that a record of user names and passwords are kept. In the 
event that this information is lost and access to the camera is no 
longer possible, the settings can be viewed or changed by 
connecting the camera to a computer with the 

Device 

Configuration Utility

, using the RS-232 or RS-485 port, 

depending on the CCFC model that was ordered. 

 

Figure 12-51 

Users and Security Settings

 

 

 

Note  

Содержание CCFC Field Camera

Страница 1: ...INSTRUCTION MANUAL CCFC Field Camera May 2016 Copyright 2016 Campbell Scientific Canada Corp...

Страница 2: ......

Страница 3: ...under guarantee or not Please state the faults as clearly as possible and if the product is out of the guarantee period it should be accompanied by a purchase order Quotations for repairs can be give...

Страница 4: ......

Страница 5: ...ore beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit...

Страница 6: ......

Страница 7: ...nsity nonvisible IR 850 nm LEDs for night vision illumination Do not make physical contact with the IR LEDs or place any body part near the IR LEDs less than 5cm while the camera is powered on When in...

Страница 8: ......

Страница 9: ...up Button Status LED 11 7 2 1 Status LED 11 7 2 2 Setup Button 12 7 3 Camera Memory 13 7 3 1 Link to Most Recent Photo and Video 13 7 3 2 FTP Photo Collection from Camera Memory 14 7 4 Modem Power Con...

Страница 10: ...6 2Video Capture 55 12 7 File Explorer 58 12 8 Settings 59 12 8 1General 59 12 8 1 1SNTP 61 12 8 2Network 62 12 8 2 1Wired Ethernet Settings 63 12 8 2 2Wi Fi Settings 64 12 8 2 3Wi Fi Access Mode 65...

Страница 11: ...ER 95 15 3 4Example Program Adding GPS Coordinates to the Photo Banner DATALOGGER 96 15 4 PakBus Neighbouring Address 97 16 Power Calculations and Timings 97 16 1 Standalone Operation 97 16 2 Operatio...

Страница 12: ...2 12 Motion Detect 43 Figure 12 13 Motion Detect Create New Profile 45 Figure 12 14 Lens Position 49 Figure 12 15 Lens Position Modal 49 Figure 12 16 Lens Position Modal in Capture Modes 49 Figure 12...

Страница 13: ...107 Figure 20 3 CCFC Mounted to Crossarm 108 Tables TABLE 4 1 Power Mode Summary 7 TABLE 6 1 CCFC Factory Default Configuration 9 TABLE 7 1 Setup Button Status LED 12 TABLE 8 1 Power I O Cable Connect...

Страница 14: ...2 24 Camera Power Modes 75 TABLE 12 25 Capture Response Time 77 TABLE 12 26 Ethernet Power Modes 78 TABLE 12 27 Wi Fi Power Modes 79 TABLE 12 28 Import Export Settings 85 TABLE 12 29 Users 89 TABLE 13...

Страница 15: ...ptions include Ethernet Wi Fi RS 232 and RS 485 The CCFC is fully web enabled with HTTP FTP and Email capabilities Campbell Scientific s PakBus protocol is supported by the CCFC for integration with C...

Страница 16: ...C Full functionality of the motorized zoom lens is available in the temperature range of 30 C to 60 C Image and video capture can still occur but the motorized lens will remain in a fixed position at...

Страница 17: ...ignal Logic Low Level 0 65 V 20 Vdc Absolute Min Logic High Level 2 0 Vdc 20 Vdc Absolute Max Communication Interfaces Ethernet 10 100 RS 232 port or RS 485 port Wi Fi supports 802 11bgn in the 2 4 GH...

Страница 18: ...claims with the shipping company Immediately check package contents against the shipping documentation Contact Campbell Scientific about any discrepancies The model number and cable length are printed...

Страница 19: ...10 seconds or by using the Power Icon on the web interface Always ensure that all cable connectors and covers are securely in place Record any changes to the IP settings of the camera This information...

Страница 20: ...rface see Section 12 4 2 External Trigger c Motion Detect Enable and configure Motion Detect Capture To set this up using the web interface see Section 12 4 3 Motion Detect 2 Select the Power Mode tha...

Страница 21: ...y On Always On 90 mA 10 20 Full Power Save Mode 10 mA 10 20 Deep Sleep Always On 6 mA 15 25 Full Power Save Mode 6 mA 15 25 Off State Always On 1 mA 90 120 Full Power Save Mode 1 mA 90 120 This table...

Страница 22: ...ements Although the CCFC is designed to be a rugged and reliable device for field use care should be taken when handling or moving it to avoid aesthetic damage Other than the desiccant there are no us...

Страница 23: ...O Port RS 232 or RS 485 RS 232 Baud Rate 115200 PakBus Address 55 There are two methods for a user to configure the CCFC camera using the web interface via Wi Fi or Ethernet connection and using the R...

Страница 24: ...ra If the power supply has an on off switch it is recommended to switch the power off before connecting the power connector to the camera When power is first applied to the camera the Status LED on th...

Страница 25: ...e up 7 2 Setup Button Status LED The Setup Button is located behind a protective cap on the camera The Setup Button also contains an integrated Status LED for user feedback 7 2 1 Status LED The Status...

Страница 26: ...uously On The camera is booting up this process takes approximately 90 sec The camera will be required to boot up whenever Power is first applied to it The camera is exiting the Off Power mode to perf...

Страница 27: ...Title will be used to organize the photos in the directory This is set up Media Settings see Section 12 6 Media Settings The use of camera memory for media storage is entirely configurable to suit the...

Страница 28: ...esired to collect a large number of files from an entire folder using the web interface is cumbersome It is recommended to access the CCFC memory using the FTP file transfer process On most Windows ma...

Страница 29: ...ly reduce the system power requirements by only turning on the modem when required to transmit a photo or video The Modem Power Control will turn on under the following conditions The camera is in one...

Страница 30: ...the last position that was in focus to perform the capture The auto focus operation attempts to focus on the most distant object in the field of view For example in a scene with mountains in the backg...

Страница 31: ...The wiring for the Power I O Cable connector assembly and which wires need to be connected for the intended camera application is as shown in Table 8 1 Power I O Cable Connections The wires can be ter...

Страница 32: ...S 232 and RS 485 communications are used for PakBus or the Device Configuration Utility Connect to an unused terminal block Yellow Modem Power Control Output This line is intended to power a communica...

Страница 33: ...jacket IP 68 rated connector at the camera end 10 inch pigtail for termination at the datalogger end 3 Single Pole 16 20AWG Grey Push Operated Connector Terminals Maximum recommended cable length is 2...

Страница 34: ...en the CCFC and a local network router cellular modem or laptop Details of the Environmental Ethernet Cable are CAT5E Shielded cable with polyurethane jacket IP68 environmentally rated RJ45 connector...

Страница 35: ...Utility Connect the camera to the serial port of a PC using the DB9 FEMALE to Terminal Block Adaptor as shown in Section 13 RS 232 Communications Once the camera is powered up this can typically take...

Страница 36: ...as a bright sky or a dark horizon the photo may contain portions that are under exposed and portions that are over exposed as with most cameras The CCFC utilizes various techniques to produce the bes...

Страница 37: ...directs the user to the camera s web interface where the camera can be configured 11 2 Setup Using Ethernet 11 2 1 Link Local IP Address Auto Configuration The CCFC supports an automatic IP address co...

Страница 38: ...odecs are available on the computer The download is available online at http www videolan org vlc Download and install the appropriate VLC media player to the PC that will be interfacing with the CCFC...

Страница 39: ...t rtsp 192 168 1 78 ipcam mpeg4 pluginspage http www videolan org type application x vlc plugin In the embed code 192 168 1 78 needs to be changed to the IP address of CCFC being used 12 1 2 UPnP Disc...

Страница 40: ...Field Camera 26 View live video Retrieve photo and video files from the camera memory Access all camera settings Create zoom set points Figure 12 1 Dashboard Desktop view Figure 12 2 Dashboard Mobile...

Страница 41: ...re is an opportunity to select a Lens Preset from a drop down and to adjust the Zoom using a slider Edit Positions directs users to the Lens Position option See Section 12 5 Lens Positions for detaile...

Страница 42: ...f the camera is the Dashboard There are no operational settings to change on the Dashboard However a manual photo capture can be initiated from this page If any settings are changed or added the Save...

Страница 43: ...ion they would like to view from use the Edit button to go to Lens Position see Section 12 5 Lens Position or adjust the zoom level of the live stream video Using the Capture Now button allows a user...

Страница 44: ...seconds see Section 7 2 Setup Button Status LED 12 2 3 Set Up Progress Bar The Set Up Progress bar is visible on every web page When proceeding through the Set Up Progress workflow to configure the C...

Страница 45: ...be viewed in the Manual Capture modal see Figure 12 7 Manual Capture Modal The quality of the capture is Lossless Download Navigates to the File Explorer to download captured photos Time and Date 24 h...

Страница 46: ...recording the live video until the number of seconds has elapsed Video pre recording allows the camera to record up to 30 seconds of video leading up to a related capture event This feature can only b...

Страница 47: ...hen Timed Capture is enabled the CCFC uses its internal clock as a trigger to initiate the capture of photos or video In addition to the primary Timed Capture event there is also a second independent...

Страница 48: ...CCFC Field Camera 34 Figure 12 9 Timed Capture Create New Profile...

Страница 49: ...5 Lens Position Selecting the green position title opens the Lens Position modal to edit the selected lens position Enable Photo Capture Toggle Initiates the capture of photos and opens the photo cap...

Страница 50: ...ion 12 8 3 2 Email Media Profile Drop down to select a configured media profile Use the Edit button to setup Media profiles via the Media Settings modal see Section 12 6 Media Settings Send via FTP To...

Страница 51: ...Lens Position Selecting the green position title opens the Lens Position modal to edit the selected lens position Enable Video Capture Toggle Enables video capture and opens the video capture settings...

Страница 52: ...FTP Destination Drop down to select a configured FTP profile Use the Edit button to setup FTP profiles via the FTP Settings modal see Section 12 8 3 1 FTP Send via PakBus Toggle Enabling initiates se...

Страница 53: ...period is 10 milliseconds msec Preferably pulses should be short in duration milliseconds No less than 1 sec between captures is recommended with no more than 5 in a 10 second period The voltage leve...

Страница 54: ...positive voltage Active Low Configures the External Trigger to capture with 0 volts Lens Position Checkbox Select 1 4 lens positions for the capture See Section 12 5 Lens Position Selecting the green...

Страница 55: ...o select a configured media profile Use the Edit button to setup Media profiles via the Media Settings modal see Section 12 6 Media Settings Send via Email Toggle Enable to initiate sending photos via...

Страница 56: ...Video Duration Sets length of video capture event Maximum is 60 seconds Pre Record Duration Sets length of video to be recorded before capture event Maximum is 30 seconds Camera must be set to Fully...

Страница 57: ...te sending videos via FTP Destination Drop down to select a configured FTP profile Use the Edit button to setup FTP profiles via the FTP Settings modal see Section 12 8 3 1 FTP Send via PakBus Toggle...

Страница 58: ...is the only user configurable parameter for Motion Detect operation A value of 1 provides the least sensitive motion detect threshold setting and a value of 99 provides the most sensitive motion detec...

Страница 59: ...cond 10 seconds for a 5MP photo Figure 12 13 Motion Detect Create New Profile TABLE 12 8 Motion Detect Settings for Photo Options Variable Allowable Values Description Enable Opens Motion Detect Creat...

Страница 60: ...reached Continuous Overwrite management will start deleting the oldest files once the camera memory is full or the allocated memory size max space setting from above is reached Sub Folder Date Format...

Страница 61: ...ings modal see Section 12 6 Media Settings TABLE 12 9 Motion Detect Settings for Video Options Variable Allowable Values Description Enable Opens Motion Detect Create New Profile to add parameters Tit...

Страница 62: ...space setting from above is reached Sub Folder Options An option is given to store photos in a sub folder named by YY MM or YY MM DD Selecting the YY MM DD option has some performance advantages when...

Страница 63: ...ited to suit a user s requirements These positions are saved to the camera memory to optimize media capture events If no lens position is set for the event the camera will continue to use the current...

Страница 64: ...s in and out close up to wide angle Manual Focus Slider Slider automatically updates when the Zoom slider is moved as the camera automatically focuses on the center of the screen The Manual Focus slid...

Страница 65: ...entimetres 0 10 100 10 200 10 300 10 400 10 500 10 600 10 700 75 800 500 900 300 1000 80 12 6 Media Settings The camera comes with four default Media Settings which can be edited Media Settings dictat...

Страница 66: ...ettings are significant in determining how the camera will operate The description of the parameters for the Photo Capture setup are outlined in Table 12 11 Photo Capture Variables Figure 12 18 Media...

Страница 67: ...Text Title Drop down None Date and Time Numerical Increment from 1 Enter the number to start the increment from Enable File Capture Toggle When viewing the photo this information will be displayed Pos...

Страница 68: ...nal temperature of the camera TABLE 12 13 Photo Resolution Details Resolution Size with Outside Banner Maximum Characters in Banner Quality Typical File Size kB 320 x 176 320 x 192 45 Lossless 32 Very...

Страница 69: ...g the Video Capture the Media Setting Edit Video Profile web page appears There are two subtabs that provide two independent types of video to be recorded The video resolution and frame rate are the t...

Страница 70: ...CCFC Field Camera 56 Figure 12 20 Media Settings Edit Video Profile Figure 12 21 Video Settings Modal...

Страница 71: ...verwritten in the camera memory every time a video is recorded Date and Time each file will have a timestamp appended to it Ex Video1_2011_01_28_14_22_10 avi Numerical Increment a unique number is app...

Страница 72: ...ubfolders as well as individual photos or videos Be cautious when using the Delete Selected function Each capture event is allocated a set amount of space on the camera memory based on the inputted Ca...

Страница 73: ...e Capture Mode see Section 12 4 Capture Modes Clicking on one of the main folders displays the contents inside Another set of subfolders will be displayed within the main folder The camera creates sub...

Страница 74: ...ith Local Time when selected the local time and date are displayed for verification Set Manually input date and time values in drop down menus provided Synch with SNTP Server a means of synchronizing...

Страница 75: ...ecting Sync with SNTP Server from the drop down opens the SNTP Server Address box where the server automatically receives time updates which can be configured See http www pool ntp org en for a list o...

Страница 76: ...cess to the web interface the browser must be restarted with the new configuration For example if the IP address of the camera is changed the changes will be accepted by clicking on the Save button Th...

Страница 77: ...ables DHCP operation of the network interface Operates as a Static IP address if Disabled unchecked IP Address 1 2 3 4 Only set if DHCP is Disabled Gain IP address from a network administrator Netmask...

Страница 78: ...le to access the wired network The Wi Fi on the camera can connect to an existing network or become a Wi Fi access point By default the camera Wi Fi will be set up as an access point with a name such...

Страница 79: ...are revealed allowing the user to customize the way the AP works Typically AP mode would be used in an installation where the camera was not sending files out via the Wi Fi interface to an external n...

Страница 80: ...be used DHCP Start Number e g 10 0 010 Start of the address range to give to connecting clients DHCP End Number e g 10 0 0 19 End of the address range to give to connecting clients AP Security None WE...

Страница 81: ...appear when the Connected to Existing Network option is selected After performing a scan for Wi Fi networks the user can quickly copy the selected network information into one of three client settings...

Страница 82: ...The network mask to use when connecting to the Wi Fi network Default Gateway The network gateway to use for Internet traffic Primary Name Saver The DNS server to use for address resolution 12 8 3 File...

Страница 83: ...be enabled in the Capture Modes see Section 12 4 Capture Modes When specifying an FTP connection the user can select between active and passive mode file transfers The default setting is passive mode...

Страница 84: ...In active mode the client establishes the command channel but the server establishes the data channel Passive In passive mode the client establishes both channels In that case the server tells the cl...

Страница 85: ...ction 12 4 Capture Modes SMTP Address Text Enter the SMTP server address that is being used Enter the SMTP server port number as part of the SMTP address if required The camera will default to Port 25...

Страница 86: ...associated with the email account When troubleshooting email connectivity use the Show Password checkbox to ensure the password entered is correct 12 8 3 3 PakBus PakBus is used to enable media files...

Страница 87: ...logger which allows for remote retrieval using the datalogger s communication device Both RS 232 and RS 485 are available The preferred setting is determined at the time of ordering Contact Campbell S...

Страница 88: ...address of the device the camera will communicate with or send files to PakBus Neighbour 0 to 4095 Physically enter the address of the PakBus device to connect to the CCFC PakBus communication lines...

Страница 89: ...ng communications Moderate Power Save Mode Not recommended Full Power Save Camera is always on Average power consumption is reduced by 50mA 12 Vdc The Ethernet is normally turned off and is only enabl...

Страница 90: ...n 6mA typically is not affected by the Ethernet Power Mode Ethernet RS 232 or RS 485 communications are non responsive in Deep Sleep mode Moderate Power Save Mode Not recommended Full Power Save Mode...

Страница 91: ...Ethernet Power Mode Ethernet Power Mode dictates the Ethernet power draw To reduce power consumption the CCFC includes the ability to control the power characteristics of the Ethernet port The specif...

Страница 92: ...is in Partially On power mode If the camera is in the Partially On power mode then incoming data packets will wake up the camera for communications Full Power Save Mode This power mode should be used...

Страница 93: ...On the other hand if the camera needs to operate from a battery for long periods of time then the Off State is more suitable There are two methods to wake the Wi Fi up when it is configured for a low...

Страница 94: ...ght that is nearly invisible to the human eye Do not look directly at the front of the camera when the LEDs are on as they can cause severe eye damage The infrared IR LEDs on the camera are used to ta...

Страница 95: ...when the camera is in night mode giving the camera extra sensitivity in dark scenes without having to use the IR LEDs When the IR LEDs are enabled and switched on the IR filter automatically switches...

Страница 96: ...Some modems require a warm up time or a period of time to register on a network The Early Power On option is there for this purpose Enter a value in seconds the maximum value that can be entered is 3...

Страница 97: ...Figure 12 44 Lens Defroster Control Always On If Prior to Capture is selected the camera will wake up prior to any of the Timed Capture schedules and turn on the heater if the temperature is below the...

Страница 98: ...Degrees Minutes Seconds or Decimal Degrees When Degrees Minutes Seconds is selected Latitude North or South and Longitude East and West must be selected from the drop down and numerical values for de...

Страница 99: ...re also compatible with the Device Configuration Utility Figure 12 49 Import Export Camera Settings TABLE 12 28 Import Export Settings Variable Options Description Upload Configuration File Choose fil...

Страница 100: ...le Download Button Downloads the configuration file to the connected device Downloading the configuration file is useful when setting up multiple cameras with the same function The option to download...

Страница 101: ...file send as is to camera Once the firmware update process is completed the Dashboard will be displayed indicating that the process is complete The camera will reboot itself It will take a few minute...

Страница 102: ...fault cameras are shipped with the security authentication disabled When Authentication is set to Enable users will be prompted for a User Name and Password before access is given Ensure that a record...

Страница 103: ...og into the interface Confirm Password Text Must be identical to the password If a user needs to be removed from the User List this must be done by a user with Admin access Remember that any deletion...

Страница 104: ...Scientific provides and to send photo files from the camera to other devices using the PakBus protocol This value is displayed on the web interface under Settings File Transfer PakBus Figure 13 1 PakB...

Страница 105: ...RS 232 Port Wire Colour Function Connection Required Red Power 9 to 30 Vdc Black Shield Pin 5 and Power Ground White Rx input Pin 3 Green Tx output Pin 2 The required RS 232 connections to a datalogge...

Страница 106: ...rface of the Device Configuration Utility Confirm that the PakBus port parameter of the Communications Setting is reading RS 485 Set the RS 485 BAUD rate to match the BAUD rate of the device being con...

Страница 107: ...ng distance telephone connections can be avoided by scheduling photo transfers from the camera to the datalogger outside the scheduled data collection time If a station is called on the hour to retrie...

Страница 108: ...to 255 characters including null terminator The camera variable names are CCFCStillBanner1 CCFCStillBanner2 CCFCVideoBanner1 CCFCVideoBanner2 The variable for controlling the window defroster is nume...

Страница 109: ...l begin the countdown again from 65 Sending a zero value using this variable will not turn off the defroster regardless of which method was used to turn it on The defroster commands should be sent to...

Страница 110: ...tt_volt Enter other measurement instructions tempstring FormatFloat PTemp 2 2f BannerString Panel Temp tempstring If TimeIntoInterval 0 5 Min Then SendVariables SendVarResult Com1 0 55 0000 400 Public...

Страница 111: ...entering the address of the PakBus device connected to the CCFC PakBus communication lines allows the neighbour to relay communication between the CCFC and the final destination for data Leave PakBus...

Страница 112: ...nds TABLE 16 1 Power Consumption Standalone Operation Power Mode Ethernet Power Save Mode Quiescent Current Draw Max 12Vdc Active Current Draw Max 12Vdc Active Duration Amp Hr Per Day 2 JPG Day Amp Hr...

Страница 113: ...uenced by two main factors the size of the photo or video and the transfer speed used to send the file The amount of time the camera is on will be increased as the size of the file becomes larger or a...

Страница 114: ...e in Quiescent Low Powered State Quiescent minutes 1440 minutes per day Active minutes Quiescent minutes 1440 22 1418 minutes Determine the power consumed by the Quiescent state in Amp Hours Quiescent...

Страница 115: ...Communications The pigtail end of the CCFC Power I O cable can be terminated directly to the datalogger wiring panel control ports COM1 4 Refer to Section 8 Cables Wiring for wiring details The CCFC...

Страница 116: ...he CCFC will not send any files using the PakBus that are greater than 2 MB 18 2 Datalogger Files Manager The Files Manager setting on the datalogger facilitates the management of jpeg and avi files t...

Страница 117: ...g or avi In Figure 18 1 this value is JPG Count dictates the maximum number of files stored with this file name If the datalogger processes more files than specified the datalogger will delete the old...

Страница 118: ...r configuration Once configured File Retrieval is used to retrieve photos and video from a datalogger Figure 19 1 File Retrieval Setup Screen Select the required Retrieval Mode for the application The...

Страница 119: ...t Directory is C Campbellsci LoggerNet If required the preferred location can be found by browsing The Max Files parameter specifies the maximum number of files that can be retrieved during each sched...

Страница 120: ...D compact flash module The devices show up in the left hand side of the File Control panel To view files of a certain device simply click on the desired device listed in the panel Figure 19 3 USR Driv...

Страница 121: ...FC Mounting Kit The camera is equipped with a set of three 20 threaded mounting holes see Figure 20 2 These mounting holes are centred along the bottom of the camera and are spaced 1 0 25 4 mm apart f...

Страница 122: ...intended target Figure 20 3 CCFC Mounted to Cross arm 21 Maintenance The CCFC requires little maintenance Keeping the camera lens window clean is important for the longevity of the camera and photo an...

Страница 123: ...longer capture times than other photo resolutions When a 5 MP photo is captured the continuous video stream is paused the photo sensor is reconfigured and then the 5MP photo is captured This longer de...

Страница 124: ......

Страница 125: ...cation device or trigger the CCFC to initiate photo or video capture Ordering part number 1 CCFCCBL1 L L is length in feet Details 20 AWG 1 pair twisted 24 AWG 2 pair individually shielded cable with...

Страница 126: ...AT5E Cable with polyurethane Jacket RJ45 Environmental Connector on one end and rugged Metal RJ45 connector on the other end Maximum length 70 m 230 ft RoHS Compliant Figure A 2 CCFCCBL2 L Environment...

Страница 127: ...CCFC Field Camera A 3 A 4 L28840 DB9 FEMALE To Terminal Block Adaptor Details DB9 FEMALE to terminal block interface with hood and hardware kit Figure A 4 L28840 DB9 FEMALE To Terminal Block Adapt...

Отзывы: