![Campbell CC5MPXWD Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/campbell/cc5mpxwd/cc5mpxwd_instruction-manual_3741587021.webp)
CC5MPX Digital Camera
9
The CC5MPX ships from the factory with the communication lines configured
for RS-232. The green wire on the cable is the CC5MPX RS-232 TX (output)
line; the white wire is the CC5MPX RS-232 RX (input) line. A connection will
also need to be made from the CC5MPX black ground to the RS-232 ground.
The CC5MPX comes with a female DB9 to terminal block accessory that
facilitates the connection from the Power and I/O Cable
to a 9-pin RS-232
(p. 15)
, for wiring details.
When power is first applied to the camera, the LED will turn on and remain
steadily on for about 90 seconds. Once the LED starts flashing, the camera has
initialized properly and is ready for operation.
DevConfig
can now be invoked. Select the
CC5MPX
as the device type and
choose the appropriate
COM
port (FIGURE
).
Once the appropriate selections are made, select the
Connect
button.
FIGURE 4-6. CC5MPX shown in Device Configuration Utility