manualshive.com logo in svg
background image

8.2

 

Electrical

 

noisy

 

environments

AC

 

power

 

lines,

 

pumps,

 

power

 

inverters,

 

and

 

motors

 

can

 

be

 

the

 

source

 

of

 

electrical

 

noise.

 

If

 

the

 

sensor

 

or

 

data

 

logger

 

is

 

located

 

in

 

an

 

electrically

 

noisy

 

environment,

 

the

 

sensor

 

should

 

be

 

measured

 

with

 

the

 

60

 

or

 

50

 

Hz

 

rejection

 

option.

8.3

 

Long

 

cable

 

lengths

Cable

 

resistance

 

can

 

cause

 

significant

 

error.

 

The

 

4-wire

 

configuration

 

is

 

the

 

best

 

configuration

 

for

 

long

 

cable

 

lengths.

The

 

heat

 

shrink

 

label

 

on

 

the

 

110PV

 

cable

 

provides

 

the

 

cable

 

resistance

 

(ohms).

 

When

 

using

 

the

  

2-wire

 

configuration,

 

subtract

 

this

 

cable

 

resistance

 

from

 

the

 

measured

 

resistance

 

value.

Additional

 

settling

 

time

 

may

 

be

 

required

 

for

 

cable

 

lengths

 

longer

 

than

 

300

 

feet,

 

where

 

settling

 

time

 

is

 

the

 

delay

 

before

 

the

 

measurement

 

is

 

made.

 

Longer

 

settling

 

times

 

can

 

be

 

typed

 

into

 

the

 

Settling

 

Time

parameter

 

in

 

the

 

BrHalf4W()

or

 

BrHalf()

instruction.

9. Maintenance

 

and

troubleshooting

NOTE:
For

 

all

 

factory

 

repairs,

 

customers

 

must

 

get

 

an

 

RMA

 

number.

 

Customers

 

must

 

also

 

properly

 

fill

 

out

 

a

 

“Declaration

 

of

 

Hazardous

 

Material

 

and

 

Decontamination”

 

form

 

and

 

comply

 

with

 

the

 

requirements

 

specified

 

in

 

it.

 

Refer

 

to

 

the

 

Read First 

page

 

at

 

the

 front 

of

 

this

 

manual

 

for

 

more

 

information.

9.1 Troubleshooting

Symptom: Temperature is NAN, –INF, –9999, –273

Verify

 

the

 

red

 

wire

 

is

 

connected

 

to

 

the

 

correct

 

single-ended

 

analog

ue 

input

 

channel

 

as

 

specified

 

by

 

the

 

measurement

 

instruction,

 

the

 

black

 

wire

 

is

 

connected

 

to

 

the

 

switched

 

excitation

 

channel

 

as

 

specified

 

by

 

the

 

measurement

 

instruction,

 

and

 

the

 

purple

 

wire

 

is

 

connected

 

to

 

data

 

logger

 

ground.

110PV Surface Temperature Probe

14

Содержание 110PV

Страница 1: ...Revision 07 2020 Copyright 2010 2020 Campbell Scientific CSL I D 897...

Страница 2: ......

Страница 3: ...under guarantee or not Please state the faults as clearly as possible and if the product is out of the guarantee period it should be accompanied by a purchase order Quotations for repairs can be give...

Страница 4: ......

Страница 5: ...digital cell phones and aerials may also not be applicable according to your locality Some brackets shields and enclosure options including wiring are not sold as standard items in the European marke...

Страница 6: ......

Страница 7: ...beginning work Wear a hardhat and eye protection and take other appropriate safety precautions while working on or around tripods and towers Do not climb tripods or towers at any time and prohibit cl...

Страница 8: ......

Страница 9: ...pe 9 7 3 Wiring 10 7 4 Data logger programming 12 7 4 1 Resistance measurement 12 7 4 2 Converting resistance measurement to temperature 12 8 Operation 13 8 1 Measurement details 13 8 2 Electrical noi...

Страница 10: ......

Страница 11: ...ng the sensor head off will likely damage both the sensor and PV module see Caution at the end of Troubleshooting p 14 l The 110PV cable must be properly strain relieved after mounting the probe to th...

Страница 12: ...ideo that describes data logger programming using Short Cut is available at www campbellsci eu videos cr1000x data logger getting started program part 3 Short Cut is an easy way to program your data l...

Страница 13: ...s value is unique for each 110PV and is printed on the heat shrink label attached to the sensor cable 4 Click on the Wiring tab to see how the sensor is to be wired to the data logger Short Cut uses a...

Страница 14: ...sh and save the program Send the program just created to the data logger if the data logger is connected to the computer 9 If the sensor is connected to the data logger check the output of the sensor...

Страница 15: ...adhesive tab on the aluminium disk fastens the 110PV to the measurement surface If the temperature may exceed 70 C also use extreme sealing tape to secure the probe to the measurement surface Features...

Страница 16: ...l range 50 to 140 C Accuracy1 Worst case 0 2 C 40 to 70 C 0 5 C 71 to 105 C 1 C 106 to 135 C Maximum Steinhart Hart linearization error 0 0024 C at 40 C Maximum cable length 304 8 m 1000 ft Disk diame...

Страница 17: ...coefficient Effects of cable resistance is discussed in Long cable lengths p 14 7 Installation If you are programming your data logger with Short Cut skip Wiring p 10 and Data logger programming p 12...

Страница 18: ...to a clean surface for its adhesive to function properly CAUTION Do not use epoxy to secure the sensor head to a PV module 7 2 2 Cable strain relief The cable must be properly strain relieved after m...

Страница 19: ...isk is adequately fastened to the measurement surface use three strips of extreme sealing tape in two places each 1 Place a strip of tape across the sensor head perpendicular to the cable and rub the...

Страница 20: ...Proper tape usage 7 3 Wiring FIGURE 7 3 p 11 provides the schematic and Table 7 1 p 11 provides the connections to Campbell Scientific data loggers Either a 4 wire half bridge or 3 wire half bridge c...

Страница 21: ...voltage input U configured for differential input1 SE single ended analogue voltage input Purple Signal reference U configured for differential input1 DIFF L differential low analogue voltage input a...

Страница 22: ...ded in the following section Complete program examples for select CRBasic data loggers can be found in Example programs p 17 If applicable please read Electrical noisy environments p 14 and Long cable...

Страница 23: ...ur data loggers Simple half bridge measurement ignoring cable resistance has a measured voltage V of V Vx 4990 4990 Rt Where Vx is the excitation voltage 4990 ohms is the resistance of the fixed resis...

Страница 24: ...settling time is the delay before the measurement is made Longer settling times can be typed into the Settling Time parameter in the BrHalf4W or BrHalf instruction 9 Maintenance and troubleshooting NO...

Страница 25: ...ld wire is connected to data logger ground and the data logger is properly grounded CAUTION If the 110PV needs to be sent to Campbell Scientific for repairs the probe must be heated to 70 to 80 C befo...

Страница 26: ......

Страница 27: ...for additional refinement NOTE Once the file is edited with CRBasic Editor Short Cut can no longer be used to edit the program it created 2 To add the Short Cut wiring information into the new CRBasic...

Страница 28: ......

Страница 29: ...f4W instruction to measure the 110PV The following table provides wiring for the example programs Table B 1 Wiring for example programs Colour Description Data logger connection BrHalf BrHalf4W Black...

Страница 30: ...le units Units T110PV_mV millivolts Units T110PV_Res Ohms Units T110PV_Temp_C Deg C Units T110PV_Temp_F Deg F Define a data table for 10 minute averages DataTable AvgTemp 1 1 DataInterval 0 10 Min 10...

Страница 31: ...nst C 8 775468 10 8 Declare variable units Units T110PV_mV millivolts Units T110PV_Res Ohms Units T110PV_Temp_C Deg C Units T110PV_Temp_F Deg F Define a data table for 10 minute averages DataTable Avg...

Страница 32: ......

Страница 33: ...ver at very low temperatures 40 C the bond strength decreases Solvent resistance No apparent degradation when exposed to splash testing of many common solvents and fluids including gasoline JP 4 fuel...

Страница 34: ...nfo campbellsci fr www campbellsci fr Germany Location Phone Email Website Bremen Germany 49 0 421 460974 0 info campbellsci de www campbellsci de India Location Phone Email Website New Delhi DL India...