manualshive.com logo in svg
background image

Important Safety Information

InStruCtIonS PertAInIng to A rISk oF FIre, eLeCtrIC ShoCk, or Injury 
to PerSonS

This manual contains important safety, operational and maintenance information. If 
you have any questions, please call 1-800-543-6400 for customer assistance.

Since the air compressor and other components (material pump, spray guns, filters, 
lubricators, hoses, etc.) used, make up a high pressure pumping system, the following 
safety precautions must be observed at all times:

CALIFornIA ProPoSItIon 65

 

This product or its power cord may contain chemicals,  including lead, 

  known to the State of California to cause cancer and birth defects or 

other reproductive harm. Wash hands after handling. 
 

You can create dust when you cut, sand, drill or grind 

  materials such as wood, paint, metal, concrete, cement, or 

other masonry. This dust often contains chemicals known to cause cancer, birth 
defects, or other reproductive harm. Wear protective gear.

Breathable Air Warning

This compressor/pump is not equipped and should not be used “as is” to supply 
breathing quality air. For any application of air for human consumption, the air 
compressor/pump will need to be fitted with suitable in-line safety and alarm 
equipment. This additional equipment is necessary to properly filter and purify 
the air to meet minimal specifications for Grade D breathing as described in 
Compressed Gas Association Commodity Specification G 7.1 - 1966, OSHA 29 CFR 
1910. 134, and/or Canadian Standards Associations (CSA).

DISCLAIMer oF WArrAntIeS

In the event the compressor is used for the purpose of breathing air application 
and proper in-line safety and alarm equipment is not simultaneously used, 
existing warranties shall be voided, and Campbell Hausfeld disclaims any liability 
whatsoever for any loss, personal injury or damage.

generAL

a.  

To reduce the risks of electric shock, fire, and injury to persons, read 
all the instructions before using the tool. Failure to follow warnings, 
dangers, and cautions could result in DEATH or SERIOUS INJURY.

b. 

Be thoroughly familiar with the controls and the proper use of the 
equipment. 

Follow all instructions. Contact your Campbell Hausfeld representative 

if you have any questions.

c. 

Follow all local electrical and safety codes as well as in the US, National Electrical 
Codes (NEC) and Occupational Safety and Health Act (OSHA).

d. 

Only persons well acquainted with these rules of safe operation should be 
allowed to use the unit.

Safety Guidelines

This manual contains information 
that is very important to know and 
understand. This information is 
provided for SAFETY and to PREVENT 
EQUIPMENT PROBLEMS. To help 
recognize this information, observe the 
following symbols.

 

  Danger indicates  

 an imminently 

hazardous situation which, if not avoided, 
WILL result in death or serious injury.
 

  Warning indicates 

a potentially 

hazardous situation which, if not avoided, 
COULD result in death or serious injury.
 

  Caution indicates  

 a potentially 

hazardous situation which, if not avoided, 
MAY result in minor or moderate injury.
 

  Notice indicates  

important 

information, that if not followed, may 
cause damage to equipment.

IMPORTANT:  

Information that 

requires special attention.

Safety Symbols

The following Safety Symbols appear 
throughout this manual to alert you 
to important safety hazards and 
precautions.

Operating Instructions and Parts Manual

www.chpower.com

Wear Eye and 

Mask Protection

Read Manual 

First

Risk of Fire

Wear Eye and 

Ear Protection

Risk of 

Electrocution

Hot Parts

Risk of 

Explosion

Risk of Falling

Risk of Fumes

4

Содержание Reference Design

Страница 1: ...O DO IT LIKE A PRO Visit us at chpower com Rapid Inflation Air Compressor Operating Instructions and Parts Manual WL6700 Series Fran aise Page 20 Espa ol p gina 40 2009 Campbell Hausfeld Scott Fetzer...

Страница 2: ...To Know Your Compressor 9 Unpacking 9 Recommended Uses for this Compressor 9 Assembly 10 Tools Required for Assembly 10 Handle Assembly 10 Inflation Hose Assembly 10 Installation 10 Location 10 Wheel...

Страница 3: ...Running HP 1 7 ISO 1217 Free Air CFM 3 8 90 psi ISO 1217 Free Air CFM 5 6 40 psi ISO 1217 Tank Capacity gallons 18 22 26 or 30 Volts Phase 120 V single Amp Draw 15 Max Working Pressure 150 Max Duty Cy...

Страница 4: ...sed existing warranties shall be voided and Campbell Hausfeld disclaims any liability whatsoever for any loss personal injury or damage General a To reduce the risks of electric shock fire and injury...

Страница 5: ...work area clean and well lighted Cluttered benches and dark areas increase the risks of electric shock fire and injury to persons b Keep bystanders children and visitors away while operating Distract...

Страница 6: ...requirements established by the American National Standards Institute Standard B19 3 1991 Safety Standard for Compressors for Process Industries Contact your air compressor manufacturer for informatio...

Страница 7: ...l assembly steps are complete and until you have read and understood the entire operator s manual u To reduce the risk of injury if any parts are missing do not attempt to assemble the air compressor...

Страница 8: ...edal On Off Switch Used to turn the compressor on and off Motor Protection If the unit is over worked a thermal switch will shut unit off If this happens turn unit OFF the ON OFF Switch wait 30 minute...

Страница 9: ...lers Intermittent Use Short powerful bursts Air chisels Air drills Automotive spray guns Die grinders Tools Not Recommended Cut off tools Dual action sanders Highspeed sanders Jitterbug sanders Straig...

Страница 10: ...and blow gun are attached make sure no pressure is in tank before replacing Recoil hose and blow gun must be installed for unit to operate properly Installation Location When assembled the tank must s...

Страница 11: ...ossible risk of electrical shock Do not use a grounding adapter with this product 2 If repair or replacement of cord or plug is necessary do not connect grounding wire to either flat blade terminal Th...

Страница 12: ...105 located as near to the gun as possible will help eliminate this moisture This compressor can be used for general inflation as well as intermittent duty air tool usage For inflation purposes this c...

Страница 13: ...it operates properly 2 Attach blow gun to the other end of the recoil hose The blow gun should ALWAYS be connected to the recoil hose 3 To inflate balls rafts etc attach inflation needle or nozzle to...

Страница 14: ...glasses pull the ring on the safety valve to release pressure from compressor tank Use your other hand to deflect fast moving air from being directed toward your face 3 The safety valve should automat...

Страница 15: ...Thermal overload protector This compressor is equipped with an automatic reset thermal overload protector which will shut off motor if it becomes overheated If thermal overload protector shuts motor...

Страница 16: ...connections fittings tubing etc 1 Check all connections with soap and water solution Tighten or remove and apply pipe dope or pipe tape to the threads then reassemble 2 Open tank drain 2 Close drain...

Страница 17: ...Motor assembly kit Includes 2 3 6 7 10 12 14 WL019100SJ 1 2 Cylinder gasket 1 3 Intake valve 1 4 Valve plate 1 5 Exhaust valve 1 6 Head gasket 1 7 Exhaust valve gasket 1 8 Head WL010500AV 1 9 Piston...

Страница 18: ...Hausfeld Serial number if any Attn Customer Service Part description and number as shown in parts list 100 Production Drive Harrison OH 45030 U S A Figure 21 Repair Parts Illustration for Rapid Infla...

Страница 19: ...tch ST196400AV 1 33 On Off Pedal WL044500AV 1 34 Eccentric Cover WL044400AV 1 35 Motor Bracket BA018300AV 1 Ref Part No Description No Qty Ref Part No Description No Qty 36 Wheel 10 OD Black Hub WA004...

Страница 20: ...Accident purchaser s abuse neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety devices If such safety devices are removed...

Отзывы: