manualshive.com logo in svg
background image

14

Operating Instructions and Parts Manual

www.chpower.com

Operation (Continued)

Figure 17 - Safety valve

enD oF oPerAtIon/StorAge

1.  Turn compressor OFF at foot pedal ON/OFF switch.
2.  Unplug power cord from wall outlet and attach to clip that is molded on the side of 

the top shroud.

3.  Drain tank of condensation as outlined in the Drain Tank section below.
4.  Wearing safety glasses, drain tank of any remaining air pressure by pulling the 

ring on the safety valve.  Use other hand to deflect any fast moving air that may be 
directed towards your face.

5.  Store compressor in a cool, dry place. 

Maintenance

 

Disconnect power source then release all pressure from the  

  system before attempting to install, service, relocate or 

perform any maintenance. Service should be performed by an authorized service 
representative.

The compressor should be checked often for any visible problems and the 
following maintenance procedures should be performed each time the compressor is 
used.

ASMe SAFety VALVe

  Do not remove or attempt to adjust the safety valve!

Check the safety valve by performing the following steps: 

1.  Plug the compressor in and run until shut off pressure is reached (see Operating 

Procedure). 

2.  Wearing safety glasses, pull the ring on the safety valve to release pressure from 

compressor tank. Use your other hand to deflect fast-moving air from being 
directed toward your face.

3.  The safety valve should automatically close at approximately 40-50 psi. If the safety 

valve does not allow air to be released when you pull on the ring, or if it does not 
close automatically, it MUST be replaced. 

DrAIn tAnk

1.  Turn compressor off at foot pedal switch.
2.  Check air pressure in tank.  To properly drain tank of condensation, tank pressure 

should be between 20-60 psi.  Drain system will not work if there is no pressure 
in the tank.  If tank pressure is above 60 psi, drain tank by pulling the ring on the 
safety valve.  The safety valve should release air and then automatically close at 
approximately 40-50 psi.  

3.  Slowly turn easy drain knob, located below the tank gauge, to the left 

(counterclockwise) 

until fluid begins to fill drain cup.  Watch draining to make sure 

drain cup does not overflow.  If there is a lot of fluid in the tank, you may need to 
close drain knob by turning fully to the right 

(clockwise)

 then remove the drain cup 

to dispose of fluid.

4.  When fluid stops draining, close drain knob by turning all the way to the right 

(clockwise)

.

5.  Lift cup up and pull out to dispose of drained fluid.  Reinsert cup, making sure to 

secure in place.

Figure 18 - Draining tank

Tank Pressure 

Gauge

Easy-Drain 

Knob

Easy-Drain Cup

Fill Line

Содержание Reference Design

Страница 1: ...O DO IT LIKE A PRO Visit us at chpower com Rapid Inflation Air Compressor Operating Instructions and Parts Manual WL6700 Series Fran aise Page 20 Espa ol p gina 40 2009 Campbell Hausfeld Scott Fetzer...

Страница 2: ...To Know Your Compressor 9 Unpacking 9 Recommended Uses for this Compressor 9 Assembly 10 Tools Required for Assembly 10 Handle Assembly 10 Inflation Hose Assembly 10 Installation 10 Location 10 Wheel...

Страница 3: ...Running HP 1 7 ISO 1217 Free Air CFM 3 8 90 psi ISO 1217 Free Air CFM 5 6 40 psi ISO 1217 Tank Capacity gallons 18 22 26 or 30 Volts Phase 120 V single Amp Draw 15 Max Working Pressure 150 Max Duty Cy...

Страница 4: ...sed existing warranties shall be voided and Campbell Hausfeld disclaims any liability whatsoever for any loss personal injury or damage General a To reduce the risks of electric shock fire and injury...

Страница 5: ...work area clean and well lighted Cluttered benches and dark areas increase the risks of electric shock fire and injury to persons b Keep bystanders children and visitors away while operating Distract...

Страница 6: ...requirements established by the American National Standards Institute Standard B19 3 1991 Safety Standard for Compressors for Process Industries Contact your air compressor manufacturer for informatio...

Страница 7: ...l assembly steps are complete and until you have read and understood the entire operator s manual u To reduce the risk of injury if any parts are missing do not attempt to assemble the air compressor...

Страница 8: ...edal On Off Switch Used to turn the compressor on and off Motor Protection If the unit is over worked a thermal switch will shut unit off If this happens turn unit OFF the ON OFF Switch wait 30 minute...

Страница 9: ...lers Intermittent Use Short powerful bursts Air chisels Air drills Automotive spray guns Die grinders Tools Not Recommended Cut off tools Dual action sanders Highspeed sanders Jitterbug sanders Straig...

Страница 10: ...and blow gun are attached make sure no pressure is in tank before replacing Recoil hose and blow gun must be installed for unit to operate properly Installation Location When assembled the tank must s...

Страница 11: ...ossible risk of electrical shock Do not use a grounding adapter with this product 2 If repair or replacement of cord or plug is necessary do not connect grounding wire to either flat blade terminal Th...

Страница 12: ...105 located as near to the gun as possible will help eliminate this moisture This compressor can be used for general inflation as well as intermittent duty air tool usage For inflation purposes this c...

Страница 13: ...it operates properly 2 Attach blow gun to the other end of the recoil hose The blow gun should ALWAYS be connected to the recoil hose 3 To inflate balls rafts etc attach inflation needle or nozzle to...

Страница 14: ...glasses pull the ring on the safety valve to release pressure from compressor tank Use your other hand to deflect fast moving air from being directed toward your face 3 The safety valve should automat...

Страница 15: ...Thermal overload protector This compressor is equipped with an automatic reset thermal overload protector which will shut off motor if it becomes overheated If thermal overload protector shuts motor...

Страница 16: ...connections fittings tubing etc 1 Check all connections with soap and water solution Tighten or remove and apply pipe dope or pipe tape to the threads then reassemble 2 Open tank drain 2 Close drain...

Страница 17: ...Motor assembly kit Includes 2 3 6 7 10 12 14 WL019100SJ 1 2 Cylinder gasket 1 3 Intake valve 1 4 Valve plate 1 5 Exhaust valve 1 6 Head gasket 1 7 Exhaust valve gasket 1 8 Head WL010500AV 1 9 Piston...

Страница 18: ...Hausfeld Serial number if any Attn Customer Service Part description and number as shown in parts list 100 Production Drive Harrison OH 45030 U S A Figure 21 Repair Parts Illustration for Rapid Infla...

Страница 19: ...tch ST196400AV 1 33 On Off Pedal WL044500AV 1 34 Eccentric Cover WL044400AV 1 35 Motor Bracket BA018300AV 1 Ref Part No Description No Qty Ref Part No Description No Qty 36 Wheel 10 OD Black Hub WA004...

Страница 20: ...Accident purchaser s abuse neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety devices If such safety devices are removed...

Отзывы: