CLeAnIng

Turn power OFF and clean dust and dirt from motor, tank, and 
air lines.

IMPORTANT:

 Unit should be located as far from spraying area 

as hose will allow to prevent over-spray from entering the pump.

AIr FILter

Check air filter to be sure it is clean. To service the air filter, tip 
the unit back, resting the  wheels and handle on the floor (See 
Figure 19). Remove the filter housing cover. Remove filter and 
blow off dirt. Replace air filter if it can not be cleaned. Place filter 
back in the housing base. Replace cover.

LubrICAtIon

This is an oilless type compressor requiring no lubrication.

therMAL oVerLoAD ProteCtor

 

This compressor is equipped with an automatic 

  reset thermal overload protector which will shut 

off motor if it becomes overheated.

If thermal overload protector shuts motor OFF frequently look 
for the following causes:

1.  Low voltage
2.  Lack of proper ventilation

 

If the thermal overload protector is actuated, 

  the motor must be allowed to cool down before 

startup is possible. The motor will automatically restart without 
warning if left plugged into electrical outlet and unit is turned on.

torque requIreMentS

Piston Bolt . . . . . . . . . . . . . . . . . . . . . . . 350 - 450 in. Ibs.

Head Bolts . . . . . . . . . . . . . . . . . . . . . . . 90 - 120 in. Ibs.

teChnICAL SerVICe

For information regarding the operation or repair of this 
product, please call  
1-800-543-6400.

15

WL6700 Series

www.chpower.com

Maintenance (Continued)

Figure 19 - Air Filter

Air Filter

Содержание Reference Design

Страница 1: ...O DO IT LIKE A PRO Visit us at chpower com Rapid Inflation Air Compressor Operating Instructions and Parts Manual WL6700 Series Fran aise Page 20 Espa ol p gina 40 2009 Campbell Hausfeld Scott Fetzer...

Страница 2: ...To Know Your Compressor 9 Unpacking 9 Recommended Uses for this Compressor 9 Assembly 10 Tools Required for Assembly 10 Handle Assembly 10 Inflation Hose Assembly 10 Installation 10 Location 10 Wheel...

Страница 3: ...Running HP 1 7 ISO 1217 Free Air CFM 3 8 90 psi ISO 1217 Free Air CFM 5 6 40 psi ISO 1217 Tank Capacity gallons 18 22 26 or 30 Volts Phase 120 V single Amp Draw 15 Max Working Pressure 150 Max Duty Cy...

Страница 4: ...sed existing warranties shall be voided and Campbell Hausfeld disclaims any liability whatsoever for any loss personal injury or damage General a To reduce the risks of electric shock fire and injury...

Страница 5: ...work area clean and well lighted Cluttered benches and dark areas increase the risks of electric shock fire and injury to persons b Keep bystanders children and visitors away while operating Distract...

Страница 6: ...requirements established by the American National Standards Institute Standard B19 3 1991 Safety Standard for Compressors for Process Industries Contact your air compressor manufacturer for informatio...

Страница 7: ...l assembly steps are complete and until you have read and understood the entire operator s manual u To reduce the risk of injury if any parts are missing do not attempt to assemble the air compressor...

Страница 8: ...edal On Off Switch Used to turn the compressor on and off Motor Protection If the unit is over worked a thermal switch will shut unit off If this happens turn unit OFF the ON OFF Switch wait 30 minute...

Страница 9: ...lers Intermittent Use Short powerful bursts Air chisels Air drills Automotive spray guns Die grinders Tools Not Recommended Cut off tools Dual action sanders Highspeed sanders Jitterbug sanders Straig...

Страница 10: ...and blow gun are attached make sure no pressure is in tank before replacing Recoil hose and blow gun must be installed for unit to operate properly Installation Location When assembled the tank must s...

Страница 11: ...ossible risk of electrical shock Do not use a grounding adapter with this product 2 If repair or replacement of cord or plug is necessary do not connect grounding wire to either flat blade terminal Th...

Страница 12: ...105 located as near to the gun as possible will help eliminate this moisture This compressor can be used for general inflation as well as intermittent duty air tool usage For inflation purposes this c...

Страница 13: ...it operates properly 2 Attach blow gun to the other end of the recoil hose The blow gun should ALWAYS be connected to the recoil hose 3 To inflate balls rafts etc attach inflation needle or nozzle to...

Страница 14: ...glasses pull the ring on the safety valve to release pressure from compressor tank Use your other hand to deflect fast moving air from being directed toward your face 3 The safety valve should automat...

Страница 15: ...Thermal overload protector This compressor is equipped with an automatic reset thermal overload protector which will shut off motor if it becomes overheated If thermal overload protector shuts motor...

Страница 16: ...connections fittings tubing etc 1 Check all connections with soap and water solution Tighten or remove and apply pipe dope or pipe tape to the threads then reassemble 2 Open tank drain 2 Close drain...

Страница 17: ...Motor assembly kit Includes 2 3 6 7 10 12 14 WL019100SJ 1 2 Cylinder gasket 1 3 Intake valve 1 4 Valve plate 1 5 Exhaust valve 1 6 Head gasket 1 7 Exhaust valve gasket 1 8 Head WL010500AV 1 9 Piston...

Страница 18: ...Hausfeld Serial number if any Attn Customer Service Part description and number as shown in parts list 100 Production Drive Harrison OH 45030 U S A Figure 21 Repair Parts Illustration for Rapid Infla...

Страница 19: ...tch ST196400AV 1 33 On Off Pedal WL044500AV 1 34 Eccentric Cover WL044400AV 1 35 Motor Bracket BA018300AV 1 Ref Part No Description No Qty Ref Part No Description No Qty 36 Wheel 10 OD Black Hub WA004...

Страница 20: ...Accident purchaser s abuse neglect or failure to operate products in accordance with instructions shall also include the removal or alteration of any safety devices If such safety devices are removed...

Отзывы: