background image

Portable Air Compressors

2

General Safety

CALIFORNIA PROPOSITION 65

 

This product or 

  its power cord may 

contain chemicals, including  lead, known 
to the State of california to cause cancer 
and birth defects or other reproductive 
harm. wash hands after handling.
 

You can 

  create 

dust when you cut, sand, 
drill or grind materials 
such as wood, paint, metal, 
concrete, cement, or other masonry. This 
dust often contains chemicals known 
to cause cancer, birth defects, or other 
reproductive harm. wear protective gear.

GENERAL SAFETY INFORMATION

Air compressors are utilized in a variety 
of air system applications. Because air 
compressors and other components 
(material pump, spray gun, filters, 
lubrications, hoses, etc.) used make up 
a high pressure pumping system, the 
following safety precautions should be 
observed at all times. Only persons well 
acquainted with these rules of safe 
operation should be allowed to use the 
air compressor.

 

 All electrical work  

   should be done 

by a qualified (licensed or certified) 
electrician. on a properly wired circuit, 
the black wires supply a voltage 
potential even when the unit is off.

 1.  Read instruction manuals for 

each component carefully, 
before attempting to assemble, 
disassemble or operate your 
particular system.

 2.  Wear safety glasses and 

use hearing protection 
when operating the 
pump or unit.

 3.  Do not stand on or use the pump or 

unit as a handhold.

 4.  Do not exceed pressure rating of 

any component in system.

 5.  Protect material lines and air lines 

from damage or puncture. Keep 
hose and power cable away from 
sharp objects, chemical spills, oil, 
solvents, and wet floors.

 6.  Never point a spray gun at oneself 

or any other person. Accidental 
discharge may result in serious injury.

 7.  Check hoses for weak or worn 

condition, before each use, making 
certain all connections are secure; 
do not use if deficiency is found. 
Notify an authorized service facility 
for examination or repair.

 

Do not run 

  unattended. leaving 

compressor in oN position may allow it to 
turn on inadvertently. To prevent this and 
possible damage from power surge, turn 
to oFF position after each use.

 8.  Release all pressures within system 

slowly; dust and debris may be 
harmful.

 

Keep 

  fingers 

away from a running 
compressor; fast moving 
and hot parts will cause 
injury and/or burns.
 

 Disconnect power  

   and depressurize 

system before servicing air compressor! 

 9.  Follow all local electrical and safety 

codes, as well as the National Electrical 
Code (NEC) and the Occupational 
Safety and Health Act (OSHA).

 10. Wiring and fuses should follow 

electrical codes, current capacity, and 
be properly grounded.

 11. Electric motors must be securely and 

adequately grounded. See grounding 
instructions and extension cord 
information, in this manual.

12. Always disconnect power source 

before working on or near a motor, or 
its connected load. If power disconnect 
point is out-of-sight, lock it in the 
open position and tag to prevent 
unexpected application of power.

13. Guard all moving parts; keep 

visitors away. Never allow children 
in work area.

14. Use only a properly grounded 

outlet that will accept a three 
pronged plug, and wear shoes to 
prevent shock hazards.

 

Be

  careful 

when touching exterior of 
operating motor; it may be 
hot enough to cause injury. 
compressor parts may be hot even if the 
unit is stopped.

15. Protect power cable from coming in 

contact with sharp objects.

16. Clean electrical or electronic 

equipment with an approved cleaning 
agent, such as dry, nonflammable 
cleaning solvent.

                               Motors, 

electrical 

equipment and controls can 
cause electrical arcs that 
will ignite a flammable gas 
or vapor. Never operate or repair the 
unit near a flammable gas or vapor. 
Never store flammable liquids or gases 
in the vicinity of the compressor.

17. To reduce fire hazard, 

keep engine/motor 
exterior free of oil, 
solvent, or grease.

18. To avoid spontaneous combustion, 

discard waste rags into approved 
metal waste cans.

19. NEVER reset safety valve or pressure 

switch. Keep safety valve free from 
paint and other accumulations. This 
provides safety against over pressure.

 

Never remove or 

  attempt to adjust 

safety valve. Keep safety valve free 
from paint and other accumulations.

20. Do regular maintenance; keep all 

nuts, bolts, and screws tight, to be 
sure equipment is in safe working 
condition .

21. Keep cleaning rags and other 

flammable waste materials in a tightly 
closed metal container and dispose of 
later in the proper fashion.

22. Drain tanks of moisture after each 

day’s use. If unit will not be used for 
a while, it is best to leave drain cock 
open until such time as it is to be used. 
This will allow moisture to completely 
drain out and help prevent corrosion 
of inside of tank.

23. Inspect tank yearly for rust, pin holes 

or any other imperfections that could 
cause it to become unsafe. NEVER 
weld or drill holes in air tank.

 

Never attempt 

  to repair or modify 

a tank! welding, drilling or any other 
modification will weaken the tank resulting 
in damage from rupture or explosion. 
Always replace worn or damaged tanks.
 

Drain liquid from 

  tank daily.

www.chpower.com

Содержание HM7510

Страница 1: ...or customer assistance Have the serial number model number and parts list with missing parts circled before calling Operating Instructions HM7500 and HM7510 Breathable Air Warning This compressor pump is not equipped and should not be used as is to supply breathing quality air For any application of air for human consumption the air compressor pump will need to be fitted with suitable in line safe...

Страница 2: ...ional Electrical Code NEC and the Occupational Safety and Health Act OSHA 10 Wiring and fuses should follow electrical codes current capacity and be properly grounded 11 Electric motors must be securely and adequately grounded See grounding instructions and extension cord information in this manual 12 Always disconnect power source before working on or near a motor or its connected load If power d...

Страница 3: ...ter to use additional air hose instead of extension cords to reach work area Wiring 1 Local electrical wiring codes differ from area to area Source wiring plug and protector must be rated for at least the amperage and voltage indicated on motor nameplate and meet all electrical codes for this minimum 2 Use a slow blow fuse type T or a circuit breaker Overheating short circuiting and fire damage wi...

Страница 4: ... number the heavier the cord Extension cords for 120V 10 Amp Unit Length of Cord ft 25 50 100 Gauge of Cord 16 14 10 Operation Pressure Switch ON OFF Switch Figure 3 In the ON position the compressor shuts off automatically when tank pressure reaches the maximum preset pressure In the 4 Portable Air Compressors Off position the compressor will not operate This switch should be in the Off position ...

Страница 5: ...reset cut out pressure is reached the compressor automatically shuts off If the compressor is left in the ON position and air is depleted from the tank by use of a tire chuck tool etc the compressor will restart automatically at its preset cut in pressure When a tool is being used continuously the compressor will cycle on and off automatically In the OFF position the pressure switch cannot functio...

Страница 6: ... filter element is dirty rotate filter cover so the holes line up with clean element material and snap cover onto housing If filter element has no clean areas replace element or entire filter Lubrication This is an oilless type compressor requiring no lubrication Storage 1 When not in use hose and compressor should be stored in a cool dry place 2 Tank should be drained of moisture 3 Hose should be...

Страница 7: ...art under Operation for proper gauge wire and cord length 3 Replace motor 4 Replace or repair 1 Check for proper fuse use time delay fuse Disconnect other electrical appliances from circuit or operate compressor on its own branch circuit 2 Check gauge chart under Operation 3 Replace or repair 1 Check with voltmeter 2 Clean filter see Maintenance section 3 Move compressor to well ventilated area 4 ...

Страница 8: ...the warranty given by the engine manufacturer which is supplied with the product G Additional items not covered under this warranty 1 All Compressors a Any component damaged in shipment or any failure caused by installing or operating unit under conditions not in accordance with installation and operation guidelines or damaged by contact with tools or surroundings b Pump or valve failure caused by...

Страница 9: ...ière d avoir le numéro de série numéro de modèle et liste de parties avec les parties manquantes encerclées avant d appeler Instructions D Utilisation HM7500 et HM7510 Avertissement D Air Respirable Ce compresseur n est pas équipé pour et ne devrait pas être utilisé comme soi pour fournir de l air respirable Pour les applications d air pour la consommation humaine il est nécessaire d équiper le co...

Страница 10: ...ereux Garder les doigts à l écart du compresseur les pièces mobiles et chaudes peuvent causer des blessures et ou des brûlures Débrancher et dissiper toute la pression du système avant de procéder à l entretien du compresseur 9 Suivre toutes les codes locaux d électicité et de sécurité ainsi que le National Electrical Code NEC et le Occupational Safety and Health Act OSHA 10 L installation des fil...

Страница 11: ...se d air du compresseur près de la vapeur un jet pulvérisé de peinture endroits de décapage au sable ou autre sources de contamination Le débris endommagera le moteur Réservé à l utilisation résidentielle Ranger à l intérieur Installation Électrique 1 Vérifier et serrer tous les boulons raccords etc avant d utiliser le compresseur 2 Utiliser le compresseur dans un endroit bien ventilé afin de le r...

Страница 12: ...er le produit seulement à une prise de la même configuration que la fiche Ne pas utiliser d adaptateur avec ce produit 12 Fr Compresseurs D Air Portatifs CORDONS PROLONGATEURS Pour éviter une perte de puissance et le surchauffage il est prudent d utiliser un tuyau additionnel au lieu d un cordon prolongateur Utiliser seulement les rallonges à 3 fils à fiches à 3 broches qui se branchent dans des p...

Страница 13: ...harge Clapet Une soupape à sens unique qui permet l arrivée d air dans le réservoir mais ne permet pas que l air se recule dans la pompe Poignée Conçue pour le déplacement du compresseur Robinet de Purge Cette soupape est située sur la base du réservoir Utiliser cette soupape pour purger l humidité du réservoir quotidiennement afin de réduire le risque de corrosion Purger le réservoir quotidiennem...

Страница 14: ...t avec le compresseur hors circuit Dépressuriser le système avant de drainer le réservoir Drainer l humidité du réservoir en ouvrant le robinet de purge sous l extrémité du réservoir et pencher pour drainer 4 Mettre le modèle hors circuit OFF et nettoyer la poussière et la saleté du moteur du réservoir des canalisations d air et des ailettes de refroidissement de la pompe REMARQUE Il faut vérifier...

Страница 15: ...t la taille de cordon prolongateur corrects 3 Remplacer le moteur 4 Remplacer ou réparer 1 Vérifier le type de fusible utiliser un fusible à retardement Débrancher les autres appareils électriques du circuit ou faire fonctionner le compresseur sur un circuit unique 2 Vérifier le tableau de calibre dans la section de Fonctionnement 3 Remplacer ou réparer 1 Vérifier avec un voltmètre 2 Nettoyer le f...

Страница 16: ...us cette garantie 1 Tous les Compresseurs a Toutes pièces détachées endommagées pendant l expédition n importe quelle panne causée par un montage ou fonctionnement du modèle sous des conditions qui ne conforment pas aux directives de montage et de fonctionnement ou dommage causée par le contact avec les outils ou les alentours b La panne de la pompe ou de la soupape causée par la pluie l humidité ...

Страница 17: ...o y la lista de partes con las partes que faltan marcadas con un círculo antes de llamar Manual de instrucciones HM7500 y HM7510 Advertencia sobre el aire respirable Este compresor cabezal no viene listo de fábrica para suministrarle aire respirable Antes de utilizarlos con este fin deberá instalarle un sistema de seguridad y alarma incorporado a la línea Este sistema adicional es necesario para f...

Страница 18: ...e podrían ocasionarle daños Mantenga los dedos alejados del scompresor cuando esté funcionando las piezas en movimiento o calientes le ocasionarían heridas y o quemaduras Desconecte la unidad y libere la presión del sistema antes de darle servicio al compresor 9 Siga todos los códigos de electricidad y seguridad locales y nacionales al igual que las medidas de seguridad laboral 10 Las conecciones ...

Страница 19: ...l compresor en un llugar limpio y bien ventilado donde la temperatura ambiente no sea mayor de 38 C 100 F Se requiere un espacio mínimo de 45 7 cm 18 pulgadas entre el compresor y la pared ya que los objectos podrían obstruir el paso de aire No coloque la entrada de aire del compresor cerca de áreas con vapor vapores de pintura chorros de arena o cualquier otra fuente de contaminación Los desperdi...

Страница 20: ...lo puede conectar al tomacorriente haga que un técnico calificado instale el tomacorriente adecuado Este producto está diseñado para funcionar en un circuito con una carga nominal de 120 v y tiene un enchufe de conexión a tierra similar al enchufe ilustrado en la Figura 2 Conecte el producto únicamente a un tomacorriente que tenga la misma configuración que el enchufe No utilice un adaptador con e...

Страница 21: ...comprimido del cabezal a la válvula de chequeo Esta tubería se calienta excesivamente durante el uso Para evitar quemaduras graves nunca la toque Válvula de chequeo Esta válvula solo permite que el aire entre al tanque y evita que éste se regrese al cabezal Mango Diseñado para mover el compresor Llave de drenaje Esta válvula está ubicada debajo del tanque Úsela para drenar la humedad del tanque di...

Страница 22: ... limpio 2 Hale el anillo de la válvula de seguridad y deje que calce en su posición normal Figura 4 Debe reemplazar la válvula de seguridad si no la puede activar o si hay fugas de aire una vez que haya soltado el anillo 3 Diariamente con el compresor apagado Despresurice el sistema antes de drenar el tanque Drene la humedad del tanque abriendo la llave de drenaje debajo del extremo del tanque e i...

Страница 23: ...quee el cordón de extensión adecuado vea la sección CORDONES DE EXTENSION página 15 2 Está conectado Chequee el fusible cortacircuito o protector de sobrecarga del motorfuse breaker or motor overload 3 Conéctelo y determine cual es el problema 4 El motor se enciende otra vez cuando se enfría apague el compresor y espere 20 minutos 5 Reemplácelo 1 Chequee con un voltimetro 2 Chequee la tabla sobre ...

Страница 24: ... con el producto G Artículos adicionales no cubiertos bajo esta garantía 1 Todos los Compresores a Cualquier componente dañado durante el envío o cualquier daño ocasionado por haber instalado u operado la unidad bajo condiciones contrarias a lo indicado en las instrucciones para instalar u operar la unidad o daños ocasionados por el contacto con herramientas o los alrrededores b Daños del cabezal ...