manualshive.com logo in svg
background image

23 Sp

FP204020, FP204100, FP204501, FP204700

2

Oilless Compressors

General Safety
Information 

(Continued)

3. Only persons well acquainted with

these rules of safe operation should
be allowed to use the compressor.

4. Keep visitors away and NEVER allow

children in the work area.

5. Wear safety glasses

and use hearing
protection when
operating the pump
or unit.

6. Do not stand on or use the pump or

unit as a handhold.

7. Before each use, inspect compressed

air system and electrical components
for signs of damage, deterioration,
weakness or leakage. Repair or
replace defective items before using.

8. Check all fasteners at frequent

intervals for proper tightness.

Motors, electrical
equipment and controls
can cause electrical arcs
that will ignite a flammable gas or
vapor. Never operate or repair in or
near a flammable gas or vapor. Never
store flammable liquids or gases in the
vicinity of the compressor.

Compressor parts may
be hot even if the unit
is stopped.

9. Keep fingers away from a running

compressor; fast moving and hot
parts will cause injury and/or burns.

10. If the equipment should start to

abnormally vibrate, STOP the
engine/motor and check
immediately for the cause. Vibration
is generally a warning of trouble.

11. To reduce fire hazard, keep

engine/motor exterior free of oil,
solvent, or excessive grease.

Never remove or 
attempt to adjust

safety valve. Keep safety valve free
from paint and other accumulations.

!

WARNING

!

CAUTION

!

WARNING

Never attempt to repair
or modify a tank!
Welding, drilling or any
other modification will weaken the
tank resulting in damage from rupture
or explosion. Always replace worn or
damaged tanks.

Drain liquid from 
tank daily.

13. Tanks rust from moisture build-up,

which weakens the tank. Make sure
to drain tank daily and inspect
periodically for unsafe conditions
such as rust formation and
corrosion.

14. Fast moving air will stir up dust and

debris which may be harmful. Release
air slowly when draining moisture or
depressurizing the compressor system.

SPRAYING PRECAUTIONS

Do not spray flammable
materials in vicinity of
open flame or near
ignition sources including the
compressor unit.

15. Do not smoke when spraying paint,

insecticides, or other flammable
substances.

16. Use a face mask/

respirator when
spraying and spray in
a well ventilated area
to prevent health and
fire hazards.

17. Do not direct paint or other sprayed

material at the compressor. Locate
compressor as far away from the
spraying area as possible to
minimize overspray accumulation
on the compressor.

18. When spraying or cleaning with

solvents or toxic chemicals, follow
the instructions provided by the
chemical manufacturer.

!

WARNING

!

WARNING

!

DANGER

Installation

LOCATION

It is extremely important to use the
compressor in a clean, well ventilated
area where the surrounding air
temperature will not be more than 100°F.

A minimum clearance of 18 inches
between the compressor and a wall is
required because objects could obstruct
air flow.

Do not locate the 
compressor air

inlet near steam, paint spray, sandblast
areas or any other source of
contamination. This debris will damage
the motor.

GROUNDING INSTRUCTIONS

1. This product is for use on a nominal

120 volt circuit and has a grounding
plug that looks like the plug illustrated
in Fig. 1. Make sure the product is
connected to an outlet having the
same configuration as the plug. This
product must be grounded. In the
event of an electrical short circuit,
grounding reduces risk of electrical
shock by providing an escape wire for
electric current. This product is
equipped with a cord having a
grounding wire with an appropriate
grounding plug. Plug must be plugged
into an outlet that is properly installed
and grounded in accordance with all
local codes and ordinances.

Improper use of
grounding plug can
result in a possible risk
of electrical shock!

!

DANGER

!

CAUTION

TEST

RESET

Figure 1 - Grounding Method

Grounding

Pin

Grounded Outlet

No. de

Numero

No. de

Numero

Ref.

Descripción

de pieza

Ctd.

Ref.

Descripción

de pieza

Ctd.

Liste de Repuestos

Sírvase darnos la siguiente información:

Puede escribirnos a:

-Número del modelo

The Campbell Group / Attn: Parts Department

-Número de Serie (de haberlo) 

100 Production Drive

-Descripción y número del repuesto según la lista de repuestos

Harrison, OH  45030 U.S.A.

Para Ordenar Repuestos Sírvase Llamar al Distribuidor Mas Cercano A Su Domicilio

1

Cubierta con mango

FP204001AV

1

2

Ensamblaje del mango

FP204002AV

1

3

Manómetro del tanque

FP204012AV

1

4

Regulador

FP204013AV

1

5

Múltiple

FP204003AV

1

6

Válvula de seguridad

V-215102AV

1

7

Interruptor

FP200343AV

1

8

Llave de drenaje

D-1403

1

9

Ensamblaje de la bomba/motor
(incluye el cable)

FP204004AV

1

10a

Tablero del circuito 
(Modelos FP204000, FP204500) FP204005AV

1

10b

Tablero del circuito 
(Modelos FP204100, FP204700) FP204122AV

1

11

Presostato

FP200354AV

1

12

Tubo de salida 

s

1

13

Accesorio de compresión

s

2

14

Tuerca de compresión

FP200353AV

2

15

Casquillo de compresión

2

16

Tornillos de la tapa - 

Artículo estándar 

M6-1.0 x 20

de ferretería

4

17

Manguera de 7,6 m (25 pies)

MP285100AV

1

18

Juego de herramientas (5 piezas)FP204008AV

1

19

Juego válvula de chequeo 

FP204010AV

1

20

Storage cover

FP204007AV

1

21

Fusible

FP200352AV

1

22

Ventilador

FP204006AV

1

s

Juego del tubo de salida
(incluye Nº 12, 13, 14 & 15)

FP200339AV

1

Juego de etiqueta adhesiva 
(no se muestra)

FP204011AV

1

www.chpower.com

100

psi

10

150

10

150

125

75

6

6

8

75

75

100

125

4

6

8

4

2

50

bar

50

2

0

25

25

psi

0

0

bar

0

20

16

1

3

6

7

5

8

11

10a
10b

9

21

15

13

14

12

19

15
13

14

22

4

2

17

18

Содержание FP204020

Страница 1: ...GARANTIA EL COMPRADOR El comprador original que no sea un revendedor del producto Campbell Hausfeld 4 PRODUCTOS CUBIERTOS POR ESTA GARANTIA Cualquier compresor de aire Campbell Hausfeld 5 COBERTURA D...

Страница 2: ...GER Installation LOCATION It is extremely important to use the compressor in a clean well ventilated area where the surrounding air temperature will not be more than 100 F A minimum clearance of 18 in...

Страница 3: ...tion and run compressor for 5 minutes 5 Turn on off switch to OFF position 6 Unplug power cord The compressor is now ready for use BEFORE EACH START UP OPERATING PROCEDURE 1 Turn regulator knob fully...

Страница 4: ...humidity is high or when a compressor is in continuous use for an extended period of time this moisture will collect in the tank When using a paint spray or sandblast gun this water will be carried f...

Страница 5: ...rea limpia y bien ventilada donde la temperatura no supera los 100 F Debe es perar a que el motor se enfr e antes de encenderlo El motor se encender autom ticamente sin previo aviso si lo deja conect...

Страница 6: ...BLANDE Complete este procedimiento antes de usar el compresor por primera vez Una vez completado no es necesario repetirlo 1 Gire la perilla del regulador totalmente hacia la derecha para abrir el flu...

Страница 7: ...re roc e en un rea bien ventilada para evitar peligros de salud e incendios 17 Nunca roc e la pintura y otros materiales directamente hacia el ADVERTENCIA ADVERTENCIA PRECAUCION ADVERTENCIA compresor...

Страница 8: ...ste producto 2003 Campbell Hausfeld Scott Fetzer www chpower com Limited Warranty 1 DURATION From the date of purchase by the original purchaser as follows Standard Duty One Year Serious Duty Two Year...

Страница 9: ...mpany 100 Production Drive Harrison Ohio 45030 T l phone 800 543 6400 3 B N FICIAIRE DE CETTE GARANTIE ACHETEUR L acheteur original sauf en cas de revente du produit Campbell Hausfeld 4 PRODUITS COUVE...

Страница 10: ...lv risation sur le compresseur 18 Suivre les instructions du fabriquant pendant la pulv risation ou le nettoyage avec des solvants ou produits chimiques toxiques AVERTISSEMENT AVERTISSEMENT DANGER Ins...

Страница 11: ...iser AVANT CHAQUE D MARRAGE PROC DURE DE FONCTIONNEMENT 1 Tourner le bouton du r gulateur compl tement vers la gauche dans le sens contraire des aiguilles d une montre 2 Connecter le tuyau d air la so...

Страница 12: ...rmettre le drainage de l humidit ATTENTION ATTENTION L HUMIDIT DANS L AIR COMPRIM L humidit dans l air comprim forme des goutelettes en arrivant de la pompe du compresseur Si l humidit est lev e ou si...

Отзывы: