Operation and maintenance instructions
Series PRE proportional pressure regulator
IO-Link version
5000030186
Ver. 03
36
A139
Pressure switch
Function
Active when the regulated pressure exceeds one of
the thresholds set. Inactive when the regulated
pressure lies within the thresholds set.
1808 6152
A140
Pressure window
Function
Active when the regulated pressure exceeds the
window set. Inactive when the regulated pressure
lies within the window set.
1809 6153
If the device is equipped with the coil vision function, the following signals are also available:
UVIX
Code
Name
Description
IO-Link code
EXE
DEC
WARNING = The control operations are not interrupted but performance is not guaranteed
A137
Warning charge coil
The charge coil is near the end of its life cycle.
180A
6154
A138
Warning exhaust coil
The exhaust coil is near the end of its life cycle.
180C
6156
18.
Limitations on use
•
Never exceed the technical specifications stated in the paragraph "General characteristics"
and the Camozzi general catalogue.
•
Except for specific intended applications, do not use the product in environments with a risk
of direct contact with corrosive gas, chemical products, salt water, water or steam.
•
If possible, do not install the device:
o
in closed and small spaces
o
exposed to direct sunlight (if necessary provide a shield)
o
near heat sources or in areas subject to sudden changes in temperature
o
near power on parts with no proper insulation
o
near conductors or electrical devices with high alternate or impulsive currents
(danger of parasitic currents);
o
near sources of high intensity electromagnetic waves (antennas) (danger of parasitic
currents and / or arcing of electric arcs).
19.
Maintenance
•
Check all conditions to prevent the inadvertent release of parts, and disconnect the power
supply to enable the discharge of residual pressure from the system before performing work.
•
Discharge all pressure from the system and the actuator itself.