If the Manual operating mode is activated on the device, it is possible to send the following
commands:
•
End manual mode: which allows to activate the Automatic operating mode.
•
Set Pressure: the target pressure value is set viathis command.
12.2.
Configurator
By clicking on the button below the image of the device (
) it is possible to
open
the
configurator.
In order to change the parameters, the device must be setted in "Manual" mode.
The parameters are divided into groups and can only be modified by the user with the necessary
permissions, furthermore, based on the version of the regulator, only some parameters will be
visible.
12.2.1.
USER SETUP
Visible parameters (only for versions with LCD):
•
Led timeout: Set the LCD screen timeout. When this time-out expires, the LED-backlit
LCD display and the backlit function keys are switched off. To switch them on again, just
press any key.
Parameters visible only for versions with analog input:
•
Fail safe analog signal: sets the regulator (either discharge or maintain the regulated
pressure) in case the analog signal is invalid.
Parameters visible only for versions with digital input (preset):
•
Preset values: set for each of the 32 combinations of the 5 digital inputs the
corresponding regulated pressure value
Parameters visible only for versions with wireless connection:
•
SSID: network name to connect.
•
Password: password of network name to connect.
•
IP address: IP address of data destination. This is the IP address of PC or gateway where
UVIX used by device is installed.
•
Host port: port number used to send and receive data with the UVIX component
designated for this task
Parameters visible in all versions:
•
Regulator Pressure Unit: serves to set the unit of measurement of the device, all
pressure values present in the configurator and on the LCD (if present, depends on the
code) will be expressed in this unit of measurement. Possible values are: psi, bar or kPa.
On the Work page the unit of measurement is always expressed in Bar.