Operation and maintenance instructions
Series PRE proportional pressure regulator
Analog /preset version
5000024670
Ver. 01
15
7.
Electrical/Pneumatic circuit
8.
Product storage and transport
•
Adopt all measures possible to avoid accidental damage to the product during transport, and
when available use the original packaging.
•
Observe the specified storage temperature range of -20 ÷ 70 °C.
9.
Installation and start-up
•
During unpacking, take great care not to damage the product.
•
Check whether there are any faults caused by product transport or storage.
•
Separate all packaging material to enable the recovery or disposal in accordance with current
standards in the country of use.
•
Where possible avoid the risk of repeated pressure surges on the circuit where the
component is installed.
•
The components must be fixed correctly using, where possible, the specific anchors and
ensuring that the fixture remains efficient even when the actuator is repeatedly used at a
high frequency and in the presence of strong vibrations.
•
Once the component is installed, ensure that all air ways are securely connected to the
respective couplings.
•
If the power supply is turned off, residual pressure may remain on the secondary side of the
regulators. The manufacturer must provide for additional exhaust components.
Recommended pneumatic circuit
•
PRE series electronic regulator can be connected to DIN rails using the relative elements PCF-
E520 fitted on the rear of the body using two M4 threaded holes.