1.  Product identification 

3

2.  General recommendations  

3

3.  General characteristics and conditions of use  

4

4.  Electrical circuit  

4

5.  Product transport and storage  

4

6.  System general description  

5

7.  Installation and start-up   

5

 

7.1  DRCS power supply

 

6

 

7.2  DRCS encoder

 

6

 

7.3  Proximity connector

 

7

 

7.4  Motor connector

 

7

 

7.5  Brake connector

 

8

 

7.6  CANopen connector

 

8

 

7.7  25-pin SUB-D connector  

 

8

 

7.8  Inputs

 

8

 

7.9  Outputs 

 

9

 

7.10  Steps to realise a movement 

 

10

 

7.11  PC requirements 

 

10

8.  Operation   

11

9.  Troubleshooting and/or exceptional circumstances  

11

10. Limitations on use  

11

11. Maintenance  

11

12. Environmental notes  

11

Содержание DRCS Series

Страница 1: ...Series DRCS drive for Stepper motors EN USE AND MAINTENANCE INSTRUCTIONS...

Страница 2: ...lation and start up 5 7 1 DRCS power supply 6 7 2 DRCS encoder 6 7 3 Proximity connector 7 7 4 Motor connector 7 7 5 Brake connector 8 7 6 CANopen connector 8 7 7 25 pin SUB D connector 8 7 8 Inputs 8...

Страница 3: ...t safety standards must be observed at all times Never interfere with the machine system before verifying that all working conditions are safe Before installation and maintenance ensure that the envis...

Страница 4: ...Quadrants Control position Encoder 100 to 5000 differential pulses revolution Control signal Input 12 opto isolated 24 V DC Control signal Output 6 opto isolated Frequency Input Step and direction inp...

Страница 5: ...allow for the recovery or disposal in accordance with current regulations in the country of use Before using the component ensure that the stated specifications and performance features correspond to...

Страница 6: ...power is applied to the POWER 48V connector use copper wires with an AWG18 cross section Warning reversing the positive and negative poles can damage the DRCS drive 7 2 DRCS Encoder A differential con...

Страница 7: ...r but the losses and operating temperature are also reduced With this scheme it is recommended to decrease the phase current by at least 30 In the parallel connection scheme the torque and speed of th...

Страница 8: ...ure starts with the rising edge Digital Inputs IN0 IN6 The digital inputs common pin EXCOM can be connected to either the negative or positive pole of the power supply Every program line set in QSet f...

Страница 9: ...d 300V If the load is inductive eg a relay it is necessary to connect a flyback diode If the load is an input module eg a PLC connect a reverse polarity protection device if not already provided by th...

Страница 10: ...ends When the motion ends the In Position output POS becomes active the Busy output BSY is deactivated The user must adopt the necessary measures to prevent damage to the system caused by voltage spik...

Страница 11: ...of alarms Limitations on use Maintenance Environmental notes 10 11 12 Never exceed the technical specifications stated in the paragraph General characteristics and the Camozzi general catalogue With t...

Страница 12: ...camozzi com Technical assistance Product inquiries and requests for support Tel 39 030 3792790 service camozzi com Product Certification Information concerning product certifications EC standards con...

Отзывы: