PM 1002308 000 00 

Summation current transformer SIRAX CT6xx line 

6/12

1. Legal information

1.1 Safety and warning notices

In this document safety and warning notices are used, which you have to observe to ensure personal safety and to prevent damage to property. 

If the warning notice is not followed death or severe personal injury 

will

 result.

If the warning notice is not followed damage to property or severe personal injury 

may

 result.

If the warning notice is not followed the device 

may

 be damaged or 

may

 not fulfill the expected functionality.

The installation and commissioning should only be carried out by trained personnel.
Check the following points before commissioning:
- that the maximum values for all the connections are not exceeded, see „Technical data“ section,
- that the connection wires are not damaged, and that they are not live during wiring,
- that the power flow direction and the phase rotation are correct.

The instrument must be taken out of service if safe operation is no longer possible (e.g. visible damage). In this case, all the connections must 
be switched off. The instrument must be returned to the factory or to an authorized service dealer.
It is forbidden to open the housing and to make modifications to the instrument. The instrument is not equipped with an integrated circuit brea-
ker. During installation check that a labeled switch is installed and that it can easily be reached by the operators.
Unauthorized repair or alteration of the unit invalidates the warranty.

Please observe that the data on the type plate must be adhered to!

The national provisions have to be observed in the installation and material selection of electric lines!

Table of Contents

1. Legal information ………………………………………………………………………………………………………… 6

1.1 Safety and warning notices ………………………………………………………………………………………………… 6
1.2 Qualified personal ………………………………………………………………………………………………………… 7
1.3 Intended use ……………………………………………………………………………………………………………… 7
1.4 Disclaimer of liability ……………………………………………………………………………………………………… 7
1.5 Feedback ………………………………………………………………………………………………………………… 7
1.6 Repair work and modifications …………………………………………………………………………………………… 7
1.7 Calibration and new adjustment …………………………………………………………………………………………… 7
1.8 Disposal ………………………………………………………………………………………………………………… 7
1.9 Return …………………………………………………………………………………………………………………… 7

2. Introduction ……………………………………………………………………………………………………………… 7

2.1 Purpose of this document ………………………………………………………………………………………………… 7
2.2 Scope of supply ………………………………………………………………………………………………………… 8
2.3 Further documents ……………………………………………………………………………………………………… 8

3. Functional description …………………………………………………………………………………………………… 8
4. Assembly and installation ……………………………………………………………………………………………… 8
5. Electrical connections …………………………………………………………………………………………………… 8
6. Technical specifications ………………………………………………………………………………………………… 9
7. Identification of the type label ……………………………………………………………………………………………10
8. Sign explanation …………………………………………………………………………………………………………10
9. Dimensions drawings ……………………………………………………………………………………………………10

Содержание SIRAX CT6 Series

Страница 1: ...ndler SIRAX CT6xx REIHE Operating manual Summation Current Transformer SIRAX CT6xx Line Camille Bauer Metrawatt AG Aargauerstrasse 7 CH 5610 Wohlen Schweiz Tel 41 56 618 21 11 Fax 41 56 618 21 21 info...

Страница 2: ...e abzuschalten Das Ger t ist an unser Werk bzw an eine durch uns autorisierte Servicestelle zu schicken Ein ffnen des Geh uses bzw Eingriff in das Ger t ist verboten Das Ger t hat keinen eigenen Netzs...

Страница 3: ...ch vom Hersteller durchgef hrt werden ffnen Sie das Geh use des Ger tes nicht Falls irgend welche unbefugten nderungen am Ger t vorgenommen werden erlischt der Garantieanspruch F r Ger te die nicht im...

Страница 4: ...nd der Gesamtverbrauch soll erfasst werden so k nnen mit Hilfe von Summenstromwandlern die Sekund rsignale der einzelnen Stromwandler aufsummiert werden Dadurch kann der Gesamtverbrauch mit nur einem...

Страница 5: ...rl schend nicht tropfend halogenfrei Dimensionen Breite H he Tiefe 112 5 x 75 x 70 mm 112 5 x 150 x 70 mm Anschl sse Anschlusstechnik M4 Schraube mit selbsttragendem Klemmb gel Maximaler Leiterquersch...

Страница 6: ...isible damage In this case all the connections must be switched off The instrument must be returned to the factory or to an authorized service dealer It is forbidden to open the housing and to make mo...

Страница 7: ...odifications shall exclusively be carried out by the manufacturer Do not open the housing of the device In case of any tampe ring with the device the guaranty claim shall lapse We reserve the right of...

Страница 8: ...ore current transformers and the total consumption is to be recorded the secondary signals of the individual current transformers can be summed up with the aid of summation current transformers As a r...

Страница 9: ...guishing non dripping halogen free Dimensions height width depth 112 5 x 75 x 70 mm 112 5 x 150 x 70 mm Connections Connection M4 screws with self lifting clamp strap Maximum conductor cross section 2...

Страница 10: ...rung CE conformity mark The device fulfills the requirements of the applicable EC directives See declaration of conformity Achtung Allgemeine Gefahrenstelle Betriebsanleitung beachten Caution General...

Страница 11: ...PM 1002308 000 00 Summation current transformer SIRAX CT6xx line 11 12 SIRAX CT610...

Отзывы: