background image

Camfil – Clean Air Solutions    7

6    Camfil – Clean Air Solutions

5 TECHNICAL SPECIFICATIONS

External dimensions, vertical model

City M Connect

City L Connect

Height (mm)

720

960

Width (mm)

340

495

Depth (mm)

345

410

Weight (kg)

15.0 (including new filters)

25.0 (including new filters)

Filter weight (kg)

 

2.0 kg (2 filters are needed)

4.1kg (2 filters are needed)

6 FAN SPECIFICATIONS

Phase

1~

Nominal voltage

VAC

230

Nominal voltage range

VAC

200 .. 240 (120 US/CAN)

Frequency

Hz

50/60

Type of data definition

ml

Speed

min

~1

3200

Power input

W

83 (110 US)

Current draw

A

0.75 (2-1.55 US)

Min. ambient temperature

ºC

-25

Max. ambient temperature

ºC

+60

 

ml=max.load; subject to alterations

7 AIR FLOW

With filter H14 with odour, VOC & ozone removal

City M Connect

City L Connect

Step

Qv 

 

[m

3

/h]

Pe 

 

[W]

LpA*  

[dBA]

Qv 

 

[m

3

/h]

Pe 

 

[W]

LpA*  

[dBA]

1

37

9

16

150

9

26

2

67

10

21

250

16

34

3

94

11

28

350

25

39

4

127

12

35

430

37

43

5

251

24

45

500

47

46

6 Max.

430

60

54

650

83

52

8 AIR FLOW DETAILS

ENG

*Tol/- 10% (Measurement performed at 1 m from the source)

Dirty air

Clean air

Filters

Fan

Содержание CITY M

Страница 1: ...CITY M CONNECT CITY L CONNECT AIR PURIFIERS USER GUIDE WWW CAMFIL COM...

Страница 2: ...t cover inlets or outlets 9 Inserting objects through inlets or outlets is forbidden 10 The unit must not be used in environments where burning smouldering objects can get into the machine 11 The unit...

Страница 3: ...r tervinning DK Dette symbol betyder at produktet skal genbruges NO Dette symbolet betyr resirkulering FI T m merkki kehottaa kierr tt m n DE Dieses Symbol bedeutet Recyceln FR Ce symbole signifie rec...

Страница 4: ...e VAC 200 240 120 US CAN Frequency Hz 50 60 Type of data definition ml Speed min 1 3200 Power input W 83 110 US Current draw A 0 75 2 1 55 US Min ambient temperature C 25 Max ambient temperature C 60...

Страница 5: ...the application takes us to the shutdown reset screen Settings when pressed the application takes you to the device settings screen ENG FAN SPEED MODE SELECTION This screen is used to select the spee...

Страница 6: ...nt where it is located SENSOR WARNINGS This screen shows a series of buttons corresponding to each of the sensors of the equipment The sensors are Particulate Matter VOC sensor CO2 sensor Fan status s...

Страница 7: ...ith the following components One City M Connect City L Connect unit Filters for the chosen purpose Quick guide Technical Manual Electrical connector If anything is missing or if you require further in...

Страница 8: ...ust always be carried out at an approved waste facility If you have any questions about this please contact your local authority or distributor for advice on correct care 18 MAINTENANCE If necessary t...

Страница 9: ...sa SWEDEN Tel 46 0 156 537 00 Web www camfil com 22 EU PROVISIONS GOVERNING THE PRODUCT This product complies with EU standards as per the Machinery Directive 2006 42 EC the Low Voltage Directive 2014...

Страница 10: ...ccording to EN1822 with an efficiency of 99 995 with integrated molecular filter for the elimination of unpleasant odours Article code 94000208 Description City L Filter Molecular H14 Plastic Quantity...

Страница 11: ...ieve that the best solutions for our customers are the best solutions for our planet too That s why every step of the way from design to delivery and across the product life cycle we consider the impa...

Отзывы: