background image

iv

Table of Contents 

CD-20SFA Sample Probe Controller 

WARRANTY - LIMITATION OF LIABILITY:  Seller warrants only title to the products, software, supplies and 

materials and that, except as to software, the same are free from defects in workmanship and materials for 

a period of one (1) year from the date of delivery.  Seller does not warranty that software is free from error or 

that software will run in an uninterrupted fashion.  Seller provides all software “as is”.  THERE ARE NO WAR-

RANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, FITNESS OR OTHERWISE WHICH EXTEND 

BEYOND THOSE STATED IN THE IMMEDIATELY PRECEDING SENTENCE.  Seller’s liability and Buyer’s 

exclusive remedy in any case of action (whether in contract, tort, breach of warranty or otherwise) arising out of 

the sale or use of any products, software, supplies, or materials is expressly limited to the replacement of such 

products, software, supplies, or materials on their return to Seller or, at Seller’s option, to the allowance to the 

customer of credit for the cost of such items.  In no event shall Seller be liable for special, incidental, indirect, 

punitive or consequential damages.  Seller does not warrant in any way products, software, supplies and materi-

als not manufactured by Seller, and such will be sold only with the warranties that are given by the manufacturer 

thereof.  Seller will pass only through to its purchaser of such items the warranty granted to it by the manufacturer.

Содержание CLIF MOCK CD-20SFA

Страница 1: ...CLIF MOCK CD 20SFA Sample Probe Controller User Manual Manual No 2350754 01 Rev 02 Class I Groups C and D Hazardous Locations...

Страница 2: ...d within the parameters stated in this manual and in conjunction with the ratings printed on the product serial tag Technical Support Contact Information Cameron Measurement Systems Division 14450 Joh...

Страница 3: ...5 How It Works 6 Hazardous Location Safety Compliance 6 Table 1 1 CD 20SFA Specifications 7 Section 2 Installation and Wiring 7 Section 3 Maintenance 8 Operational Test 8 Basic CD 20SFA Check Out 9 S...

Страница 4: ...ler s liability and Buyer s exclusive remedy in any case of action whether in contract tort breach of warranty or otherwise arising out of the sale or use of any products software supplies or material...

Страница 5: ...control card potentiometer Alarm delays can range from 5 seconds to 6 minutes An explosion proof housing encloses the complete assembly and two in NPT holes allow connection of the line power and inpu...

Страница 6: ...rols the speed of the motor at about 12 rpm and current feedback limits motor current to 3 amperes The pulse input be closed for at least 5 msec to produce a start pulse An electronic square wave inpu...

Страница 7: ...bly earthed and installed by qualified personnel in accordance with the prevailing local electrical wiring regulations and safety standards The CD 20SFA controller mounts directly to the C Series samp...

Страница 8: ...failure alarm relay contact to 1TB 3 and 1TB 4 The contact will remain open for as long as sampling occurs within the alarm delay period This contact is rated for 90 VA resistive and 30 VA inductive...

Страница 9: ...to 1TB 5 and 1TB 6 2 Mount the CD 20SFA to the sample probe and hand tighten the DC 2 coupling 3 Verify that the product line is full and pressurized 4 Reconnect input power to the CD 20SFA 5 Hold a...

Страница 10: ...D1 a 33V crowbar zener diode pro vides over voltage protection for the rest of the circuit Diode D2 prevents current flow if VDC power is connected to the common terminal and a ground is connected to...

Страница 11: ...mity switch is not sensing the high points of the cam Check proximity switch and cam alignment CD 20SFA control failure power supply board Return to factory for replacement of CD 20SFA motor control a...

Страница 12: ...R U S S I A 603 5569 0501 ms kl c a m com...

Отзывы: