Important Safety Information

Symbols and Terms Used in this Manual

!

   WARNING: 

This symbol identifies information about practices or circumstances that can lead to per

-

sonal injury or death, property damage, or economic loss.

CAUTION:   Indicates actions or procedures which if not performed correctly may lead to personal 

injury or incorrect function of the instrument or connected equipment.

Important:  Indicates actions or procedures which may affect instrument operation or may lead to an 

instrument response which is not planned.

This product must be operated within the parameters stated in this manual and in conjunction with 

the ratings printed on the product serial tag.

Technical Support Contact Information

Cameron

Measurement Systems Division

14450 John F. Kennedy Blvd.

Houston, TX 77032

Phone: 1-800-654-3760; 281-582-9500

Fax: 281-582-9599

Clif Mock is a trademark of Cameron International Corporation (“Cameron”).

© 2013 Cameron International Corporation (“Cameron”). All information contained in this publication is 

confidential and proprietary property of Cameron. Any reproduction or use of these instructions, drawings, or 

photographs without the express written permission of an officer of Cameron is forbidden.

All Rights Reserved.

Printed in the United States of America.

Manual No. 2350754-01, Rev. 02 

September 2013

Содержание CLIF MOCK CD-20SFA

Страница 1: ...CLIF MOCK CD 20SFA Sample Probe Controller User Manual Manual No 2350754 01 Rev 02 Class I Groups C and D Hazardous Locations...

Страница 2: ...d within the parameters stated in this manual and in conjunction with the ratings printed on the product serial tag Technical Support Contact Information Cameron Measurement Systems Division 14450 Joh...

Страница 3: ...5 How It Works 6 Hazardous Location Safety Compliance 6 Table 1 1 CD 20SFA Specifications 7 Section 2 Installation and Wiring 7 Section 3 Maintenance 8 Operational Test 8 Basic CD 20SFA Check Out 9 S...

Страница 4: ...ler s liability and Buyer s exclusive remedy in any case of action whether in contract tort breach of warranty or otherwise arising out of the sale or use of any products software supplies or material...

Страница 5: ...control card potentiometer Alarm delays can range from 5 seconds to 6 minutes An explosion proof housing encloses the complete assembly and two in NPT holes allow connection of the line power and inpu...

Страница 6: ...rols the speed of the motor at about 12 rpm and current feedback limits motor current to 3 amperes The pulse input be closed for at least 5 msec to produce a start pulse An electronic square wave inpu...

Страница 7: ...bly earthed and installed by qualified personnel in accordance with the prevailing local electrical wiring regulations and safety standards The CD 20SFA controller mounts directly to the C Series samp...

Страница 8: ...failure alarm relay contact to 1TB 3 and 1TB 4 The contact will remain open for as long as sampling occurs within the alarm delay period This contact is rated for 90 VA resistive and 30 VA inductive...

Страница 9: ...to 1TB 5 and 1TB 6 2 Mount the CD 20SFA to the sample probe and hand tighten the DC 2 coupling 3 Verify that the product line is full and pressurized 4 Reconnect input power to the CD 20SFA 5 Hold a...

Страница 10: ...D1 a 33V crowbar zener diode pro vides over voltage protection for the rest of the circuit Diode D2 prevents current flow if VDC power is connected to the common terminal and a ground is connected to...

Страница 11: ...mity switch is not sensing the high points of the cam Check proximity switch and cam alignment CD 20SFA control failure power supply board Return to factory for replacement of CD 20SFA motor control a...