6
DMX
IT
ALIANO
POLSKI
ESP
AÑOL
FRANCAIS
DEUTSCH
ENGLISH
6
NET IN
RJ45 network connector to connect with an Art-Net or sACN network. When setting up the network, use cables of category CAT-5e or better.
7
NET OUT
RJ45 network connector to connect additional Art-Net-capable or sACN-capable devices with a network. When setting up the network, use
cables of category CAT-5e or better.
8
ANTENNA FOR W-DMX™
The antenna for W-DMX™ control remains in its holder during operation (= operating position).
11
10
9
9
PRESSURE-SENSITIVE LC-DISPLAY WITH BACKLIGHTING
Thanks to the pressure-sensitive LC display, the device can be operated directly from the display (can be used with gloves). The display
shows the currently active operating mode (main display), the menu options in the Options menu, and the numerical values or operating
status for certain menu options. If there is no control signal to the device, the display will begin to flash. This flashing will stop as soon as a
control signal is received (DMX and Slave mode, ArtNet and sACN).
10
TOUCH-SENSITIVE CONTROL FIELDS
MODE - Press MODE (repeatedly) to go one level higher in the menu structure to the main display.
UP
and DOWN
- Selects the individual menu options in the main menu (DMX address, operating mode, etc.) and in the submenus.
ENTER - Starting from the main display, press ENTER to go to the main menu. In the main menu, press ENTER to access the menu level
where you can change values. You can also confirm value adjustments by pressing ENTER.
LEFT
and RIGHT
- Use these buttons to change the value, for instance the DMX address, as desired.
11
USB INTERFACE
USB interface to update the device firmware. In the
Service menu
, set
USB Update
to
ON
. Download, when available, the current
firmware from the product page at www.cameolight.com, unzip it, and copy the files to a folder without any special characters on a USB
stick. Disconnect the moving head from the power and all input connections (DMX / Ethernet), connect the USB stick via the USB port, and
then reconnect the moving head to the power. The USB stick will be automatically detected and shown on the display. Now navigate to the
corresponding folder on the USB stick and confirm this via “ON”. The update process will begin. Do not remove the USB stick or disconnect
the moving head from the power during the update process.
The battery-powered display can be activated even if the device is not connected to the power. To do so, press and hold MODE for a period
of 4 seconds. You can now view device information and change and save system settings, even if the device is not connected to the power.
The external control of the spotlight will not activate in this case. This means that the display will show that there is no control signal
present, even if there is one present for the device.