SETTING THE DMX START ADDRESS (DMX Address)
Access the selection menu by pressing MODE. Using the UP and DOWN control keys, now select the “DMX Address” menu option and
confirm via ENTER. Use the UP and DOWN keys to set the desired DMX start address and confirm this entry via ENTER. The main screen
now displays the operating mode and DMX start address and automatically activates the DMX operating mode.
DMX Address
DMX Address
001 - 510
DMX-Mode
DMX-Address: xxx
ENTER
UP/DOWN
ENTER
Main display
SETTING DMX MODE
You can access the options menu by pressing MODE. Using the UP and DOWN control keys, now select the “DMX Mode” menu option and
confirm by selecting ENTER. Use the UP and DOWN keys to select the desired DMX mode (3CH mode / 1CH mode) and then press ENTER to
confirm your selection. The main screen now displays the mode and DMX start address and automatically activates the DMX mode. You can find
detailed DMX tables for both DMX modes in these instructions under “DMX CONTROL”.
DMX-Mode
DMX-Address: xxx
Main display
DMX Mode
3CH Mode
1CH Mode
ENTER
UP/DOWN
/
ENTER
STAND ALONE MODE (Stand Alone)
Stand Alone mode makes it possible to manually configure the fog discharge of the machine using values of 1% to 100%. Access the selection
menu by pressing MODE. Using the UP and DOWN control keys, now select the “Stand Alone” menu option and confirm by pressing ENTER 2x.
Using the UP and DOWN control keys, now set the desired value and confirm via ENTER.
Main display
Stand Alone
Stand Alone
Pump
ENTER
UP/DOWN
ENTER
Pump Value
1% - 100%
ENTER
Stand Alone mode
Pump Value: x%
TIMER MODE (Timer)
Timer mode makes it possible to manually configure the fog discharge of the device using values of 1% to 100%, as well as the output
duration and the interval at which the discharge is to begin. Access the selection menu by pressing MODE. Using the UP and DOWN control
keys, now select the “Timer” menu option and confirm via ENTER. Now select between “Timer Pump” (output quantity), “Timer Duration”
(output duration), and “Timer Interval” (output interval) via UP and DOWN, confirm with ENTER, and set the desired value using UP and
DOWN respectively. Confirm each entry via ENTER.
Timer
ENTER
UP/DOWN
Main display
Timer mode
Duration/Interval xSec
ENTER
Timer
Pump
Pump Value
1% - 100%
ENTER - UP/DOWN
/
/
Timer
Duration
Duration Time
1sec - 60sec
ENTER - UP/DOWN
ENTER
Timer
Interval
Interval Time
1sec - 60sec
ENTER - UP/DOWN
ENTER
SLAVE MODE (Slave)
Access the selection menu by pressing MODE. Using the UP and DOWN control keys, now select the “Slave” menu option and confirm via
ENTER. Connect the slave and master unit (same model, same software version) using a DMX cable (Master DMX OUT - Slave DMX IN), and
activate Stand Alone or Timer mode on the master unit. The slave unit will now follow the master unit.
ENTER
Slave
Slave mode
Main display