Before replacing the canister or refilling it with fog fluid, disconnect the fog machine from the power supply (unplug the power plug).
A special canister lid with ventilation valve and intake hose, suitable for 5l Cameo fog fluid canister, is included in delivery (canister not
included). Place a full Cameo fog fluid canister upright in front of the fog machine and unscrew the canister lid. Now take the included
special cover and insert the ventilation valve hose and the intake hose (no. 15 and 16) into the canister and screw the special cover onto the
canister tightly. The sinter filter on the intake hose ensures that contaminant particles do not get into the system and that the hose end is
always at the lowest point of the canister. Now push the canister into the canister compartment and secure it using the Velcro strap (11); a
valve in the special cover prevents fog fluid from escaping. Now connect the fluid hose of the fog machine to the special cover (see no. 13).
To remove a fluid canister, please first loosen the fluid hose from the special cover.
10
CANISTER COMPARTMENT
Canister compartment for a 5l canister of Cameo fog fluid.
11
VELCRO STRAP
Velcro strap to attach the fluid canister.
12
SEALING CAP FOR FLUID HOSE
Remove the sealing cap from the fluid hose in order to connect the hose to the special canister cover. If the fluid hose is not connected to
the canister cover, close it using the sealing cap.
13
FLUID HOSE
Fluid hose with hose nozzle and black gasket. Connect the fluid hose on the canister cover by inserting the hose nozzle into the quick
coupler until the locking mechanism engages. Verify that the connection has a firm hold. To release the fluid hose, press the spring-loaded
release button (14).
14
RELEASE BUTTON
To release the fluid hose from the special cover, press the spring-loaded release button of the quick coupler.
15
VENTILATION VALVE
Ventilation valve with associated hose.
16
INTAKE HOSE
Intake hose with sinter filter.
OPERATION
NOTES
• After connecting to the power supply, “Welcome to Cameo”, the model designation, and the software version will display one after the
other. At the same time, the vaporizer will heat up (approx. 7 minutes), during which “Heating ...” will be shown on the display; system
settings can be applied as needed during this time.
• After the heating phase is complete, “Ready!” will display briefly and then the operating mode previously selected will activate.
• When the heating phase is complete, fog will only release when the main screen shows one of the available operating modes (DMX, Stand
Alone, Timer, Slave mode); the fog discharge halts as soon as one of the menu options is chosen from the options menu or submenu.
• Do not operate the fog machine without fog fluid! When the canister runs out during use, the fluid pump is switched off automatically for
protection purposes, “Low Liquid Protection” is shown on the display, and the canister light simultaneously starts to flash. Disconnect the
fog machine from the power supply before changing the canister or filling it with fog fluid. Then, use the “Instant Fog” function (maximum
fog discharge) in order to completely fill the fluid hose with fog fluid again, in order to prevent the automatic pump switch-off from reactivating.
• In order to remove fluid residue in the vaporizer system of your fog machine and thus ensure a long device service life, clean the vaporizer
system regularly (approx. every 60 operating hours). To do so, use the special Cameo cleaning fluid for fog machines and follow the
instruction on the bottle label.