CAMEC ELITE PRO
®
2
EM305
Ref: ELITE PRO 2 EM305-0715Rev.A.
8
INSTALLATION - ELECTRICAL/ELECTRONIC COMPONENTS
Make sure the 12V supply from the battery and any 240V electricity supply are disconnected.
• Remove battery cable terminals and disconnect any external electrical power before starting work.
• Find a suitable place for the electronic control unit (4), such as a storage area, under a seat or a bed. Make sure
this place is dry and close to the battery (40cm to 60cm). The electronic control unit can be mounted vertically
on a side wall or be mounted flat. When mounted vertically, the connections must point downwards to avoid any
short-circuits by objects falling into it.
• Fix the electronic control unit securely into position with two screws M5x40 (33).
Note:
if the provided screws are
not of suitable length or type for the desired location/material please substitute these as appropriate.
•
Drill a 25mm hole through the floor of the caravan approximately 150mm centrally in front of the control unit (4)
terminals.
Caution! Take extra care to avoid any chassis members, gas pipes and electrical wires!
• Route and connect the motor-cables in accordance with wiring diagram (Fig. 8) (red = positive, black = negative).
The wiring diagram (Fig. 8 + Table. A) below depicts the wiring route when installing the motor units in front of the
wheels/axle towards the ‘A’ frame.
Table A
Table B
FRONT OF AXLE FITTING
REAR OF AXLE FITTING
(4,6mm2 cables)
(4,6mm2 cables)
Motor unit A Positive (+) cable to terminal 4
Motor A Positive (+) cable to terminal 1
Motor unit A Negative (-) cable to terminal 3
Motor A Negative (-) cable to terminal 2
Motor unit B Positive (+) cable to terminal 2
Motor B Positive (+) cable to terminal 3
Motor unit B Negative (-) cable to terminal 1
Motor B Negative (-) cable to terminal 4
Automatic engaging system (1,5mm2 cables):
Automatic engaging system (1,5mm2 cables):
Motor unit A: Positive (+) cable to terminal d
Motor unit A: Positive (+) cable to terminal b
Motor unit A: Negative (-) cable to terminal c
Motor unit A: Negative (-) cable to terminal a
Motor unit B: Positive (+) cable to terminal b
Motor unit B: Positive (+) cable to terminal d
Motor unit B: Negative (-) cable to terminal a
Motor unit B: Negative (-) cable to terminal c
Please refer to Table B (below) for
fitment of the motor units to the rear of
the axle.