background image

1

2

3

4

5

21

22

23

17

12

13

20

18

6

7

8

11

14

15

16

19

10

9

ENGLISH

P.

 

44

 - 

M

an

u

al

 c

od

e: 

31

9

U

3

3

31

9

U

3

3

 ve

r.

 

1.

0

1.

0

 05

/2

0

11

 © C

A

M

E c

an

ce

lli auto

m

ati

ci

 s.p.a. - T

h

e d

ata a

n

d i

nf

or

m

ati

on

 in

 th

is

 m

an

u

al

 m

ay b

e c

h

an

g

ed at a

ny tim

e a

n

d w

ith

ou

t o

b

lig

ati

on

 o

n th

e p

art of C

am

e C

an

ce

lli A

uto

m

ati

ci

 S

.p.a. to n

otify s

ai

d c

h

an

g

es.

4.2 Main components

        

Warning! Before acting on the eqipment, cut off the main power supply and disconnect 
the emergency batteries (if present).

             

Before beginning to install, the following is necessary:

• Check that the fastening point of the control panel is protected from accidental impacts, and that the surfaces used for fastening are 

solid, and that the fastening is done with proper screws, plugs.

• Set up a suitable omnipolar cut-off device, with distances greater than 3 mm between contacts, with sectioned power source

• 

 Check that any connections inside the container (made for continuity purposes of the protective circuit) are fi tted with extra 

insulation compared to other internal conductive parts.

• Set up proper conduits and electric cable raceways, making sure these are protected from any mechanical damage. 

5 Installation

5. 1 Preliminary checks

Transformers

1. 

Speed adjuster connectors

2. 

Terminal board for connecting the 

3. 

002LB18 card (if unused, make sure that 
bridges are connected among A-B;C-D; 
E-F; G-h)

 Accessories fuse 

4. 

Card fuse

5. 

Amperometric sensitivity during travel 

6. 

adjustment  trimmer    

Amperometric sensitity during travel 

7. 

adjustment trimmer

    Amperometric  sensitivity  during 

8. 

slowdown adjustment trimmer

Opening / closing strike zone adjustment 

9. 

trimmer

Automatic closing adjustmet trimmer    

10. 

M2 closing delay adjstement trimmer  

11. 

10-Dip switch selector function

12. 

LED to signal radio code/ ACT counter  

13. 

Code memorising buttons

14. 

Selection jumper B1-B2 / cycle lamp

15. 

Radio frequency card socket

16. 

Line fuse

17. 

Connection terminals

18. 

4-Dip switch function selector

19. 

Selection jumper for command type for 

20. 

button on 2-7

Electro lock fuse

21. 

M1 motor fuse

22. 

M2 motor fuse

23. 

            

 Installation must be carried by skilled, qualified technicians in accordance with current regualtions.

Содержание ZL19N

Страница 1: ...English EN Z CONTROL PANELS INSTALLATION MANUAL ZL19N CONTROL PANEL FOR 24V GEARMOTORS 319U33EN...

Страница 2: ...the command devices and accessories are powered by 24V Warning The overall power of the connected accessories must not exceed 40 W overall load The control panel features an amperometric device whih c...

Страница 3: ...ABS container protection rating IP54 working temperature 20 55 C You can also connect gate open warning lamp the cycle lamp the electro lock the 002LB18 for emergency operations in case of power outa...

Страница 4: ...ation compared to other internal conductive parts Set up proper conduits and electric cable raceways making sure these are protected from any mechanical damage 5 Installation 5 1 Preliminary checks Tr...

Страница 5: ...ecure the base of the panel in a safe area yes max 6 mm Head with to 5 3 Anchoring and installing the box Perforate the marked holes and insert the cable glands with corrugated tubes for the electrica...

Страница 6: ...e changed at any time and without obligation on the part of Came Cancelli Automatici S p a to notify said changes 6 Electrical connections brown brown blue 2 FROG 24 V motors 1 FROG 24 V motor 2 FERNI...

Страница 7: ...60 Hz frequency Accessories power source Lighting and warning devices Gate open warning light Contact rated for 24 V 3 W Max Warns of open gate position turns off when gate is closed Flashing light co...

Страница 8: ...r safety devices like photocells sensitive edges and other devices that comply with EN 12978 regulations While the gate is closing opening the contact will invert movement until it is fully openend If...

Страница 9: ...ECK that THERE ARE NO JUMPER BRIDGES between contacts 2 C3 2 C1 and if the contacts are unused exclude them via Dip switch 8 and 10 6 1 Electrical connection for photocells functionalities test Stop b...

Страница 10: ...2 1 2 3 4 ON 5 6 7 8 9 10 CH1 CH2 RA2 RC2 C FA1 FC1 C FA2 FC2 C RA1 RC1 C TERMICO 3P 7 C1 C3 1 2 3 ENGLISH P 10 10 Manual code 319U33 319U33 ver 1 0 1 0 05 2011 CAME cancelli automatici s p a The dat...

Страница 11: ...djusted to between 2 and 120 seconds DELAY 2M Adjusting the M2 waiting time for each closing The waiting time can be adjusted to between 1 and 15 seconds Warning minimum sensitivity maximum power Afte...

Страница 12: ...M 433 92 AF43TW TWIN KeyBlock AM 433 92 AF43SR ATOMO AM 40 685 AF40 TOUCH AM 863 35 AF868 TOP 9 Activating the radio command Connect the antenna cable to the terminals Antenna Radio frequency card Pos...

Страница 13: ...U33 ver 1 0 1 0 05 2011 CAME cancelli automatici s p a The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S p a to notify...

Страница 14: ...ED ashes ON and OFF 2 Press the button on the transmitter to be memorised The LED will stay ON to con rm memorisation is OK Flashing LED LED on CH1 Channel for direct function command to gearmotor con...

Страница 15: ...id waste management dumps or recycling plants Other components i e electronic cards remote control batteries etc may contain hazardous substances These must therefore be handed over the specially auth...

Страница 16: ...Automation Solutions Pvt Ltd Automation Solutions Pvt Ltd A 10 Green Park 110016 New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A 11...

Отзывы: