SERIE
RODEO
22
CONNECTION OF ACCESSORIES TO THE PANEL
FOREWORD
To facilitate the wiring procedure, the entire length of the beam is equipped with a space for lodging and distributing
the cables.
Two no.2 (common) terminals have been provided on the terminal board for connection of accessories.
The power cables should be arranged on the left side of the beam, where the transformer is located.
The mains power and ground connection are connected to this transformer.
SEQUENCE OF CONNECTIONS
✔
CONNECT
OUTER
SENSOR
TO
TERMINALS
2-R1
ON
THE
TERMINAL
BOARD
IN
THE
ELECTRICAL
CABINET
✔
CONNECT
INNER
SENSOR
TO
TERMINALS
2-R2
ON
THE
TERMINAL
BOARD
IN
THE
ELECTRICAL
CABINET
✔
CONNECT
SENSOR
POWER
TO
TERMINALS
10-11
ON
THE
TERMINAL
BOARD
IN
THE
ELECTRICAL
CABINET
✔
CONNECT
MAINS
POWER
(1)
TO
THE
RELATIVE
TERMINALS
ON
THE
TRANSFORMER
(2)
✔
CONNECT
THE
GROUND
LEAD
TO
THE
RELATIVE
TERMINAL
ON
THE
TRANSFORMER
(1)
P
ROTECTED
BY
30
M
A
DIFFERENTIAL
SAFETY
SWITCH
+ 5A
CIRCUIT
BREAKER
(
AS
FOR
I
TALIAN
LAW
46/90)
(2)
I
F
24V
A
.
C
.
POWER
IS
USED
,
THIS
CONNECTION
CAN
BE
MADE
DIRECTLY
ON
THE
TERMINAL
BOARD
IN
THE
ELECTRICAL
CABINET
.
For 001MA7032
The leads for connecting the two batteries have been provided. Simply connect the batteries together using the
bridge connection cable supplied with the system.
For 001MF9011-9111
All that is needed is to insert the amplifier card into its appropriate place after connecting the sensors.
N.B.: If the card is not used, set dip switch 3 to ON (4-way dip switch).
No other connections are required. Bridge connection 2-C1 remains connected.
10
11
1
2
C1
Ri
M
R2
R1
2
F1 F2 ES ES
TX RX GND
1 2 3 4 5 6 7
MF9011 - MF9111
MA7032
1 2 3 4 5 6 7 8
2
1
3
4
5
6
7
8
9 10
O
N
2
1
3
4
O
N
RESET
APRE
MA7012
BUSSOLA
MA7041
P.R.AP
AP/PARZ
TCA
V.RALL.CH V/CH
V/AP
P.R.CH
FRENO V.RALL.AP.
FUSIBILE
ACCESS ORI
1,6A
-
+
M
N
E
+
S
S
E
-
-
BATT.
+
24AC
24AC
1 2 3 4 5 6 7
ENTRY
EXIT
CLOSED
EMERGENCY
SELECTION
Cancelli Automatici
Connection for function
switch MA 7012
Connection for function
switch MA 7041
C Nc 1 0
A2 C1 A1
A C
L1 L2
230V a.c.
Power supply
Fuse 2A 250V
+
_
Emergency battery
+
_
12 V 1.2Ah
12 V 1.2Ah
Bridge connection
for set of batteries
MF9011-9111
MA7032
F1
F2
E
s
E
s
230V
24V