WARNING!

Important instructions for the safety of people: 

READ CAREFULLY!

Foreword

• Use of the products must be restricted to its intended use 
(i.e. that for which it was expressly built for). Any other use is 
to be considered dangerous. Came Cancelli Automatici S.p.A. 
is not liable for any damage resulting from improper, wrongful 
or unreasonable use •  Keep these warnings with the installa-
tion and use manuals issued with the automated system.

Before installing 

(preliminary check: in case of a negative 

outcome, do not proceed before having 

complied with the safety obligations)

• Make sure that the parts you intend to automate are in 
good working order, and that they are  properly balanced 
and  aligned.  Also,  make  sure  that  proper  mechanical  stops 
are already in place • If the operator will be installed at a 
height  of  less  than  2.5  m  from  the  ground  or  other  access 
level, check whether you will need any protections and/or 
warnings • Any gate leaves, fi tted with pedestrian entrances, 
onto which you will install an operator, must have a blocking 
mechanism when the gate is in motion • Make sure that the 
opening of the automated gate is not an entrapment hazard 
as regards any surrounding fi xed parts • Do not mount the 
operator  upside  down  or  onto  any  elements  that  may  fold 
under its weight. If needed, add suitable reinforcements at 
the points where it is secured • Do not install onto gates on 
either an upward or downward slope (i.e. that are not on fl at, 
level ground) • Check that any lawn watering devices will not 
wet the gearmotor from the bottom up.

Installation

• Carefully section off the entire site to prevent unauthorised  
access, especially by minors and children • Be careful when 
handling operators that weigh more than 20 Kg (see installa-
tion manual). In such cases, employ proper weight handling 
safety equipment • All opening commands (e.g. buttons, key 
selectors, magnetic detectors, etc.) must be installed at least 
1.85 m from the gate’s area of operation perimeter - or where 
they cannot be reached from the outside of the gate. Also, 
the direct commands (e.g. push button, or proximity devices, 
etc.) must be installed at a height of at least 1.5 m and must 
not be accessible to the public • All ‘maintained action’ com-
mands, must be placed where the moving gate leaves, transit 
areas and driveways are completely visible • If missing, ap-
ply a permanent label that shows the position of the release 
mechanism • Before delivering to the client, verify that the 
system is EN 12453 (impact test) standard compliant. Make 
sure that the operator has been properly adjusted and that the 
safety and protection devices, as well as the manual release 

are working properly • Where necessary and in plain sight, 
apply the Warning Sings (e.g. gate plate).

Special instructions and 

advice for users

• Keep the gate’s area of operation clean and clear of any 
obstacles. Trim any vegetation that may interfere with the 
photocells • Do not allow children to play with the fi xed com-
mand  devices,  or  in  the  gate’s  area  of  operation.  Keep  any 
remote control devices (i.e. transmitters) away from the chil-
dren as well • Frequently check the system, to see whether 
any anomalies or signs of wear and tear appear on the moving 
parts, on the component parts, on the securing points, on the 
cables and any accessible connections. Keep any joints (i.e. 
hinges)  lubricated and clean, and do the same where fric-
tion may occur (i.e. slide rails) • Perform functional tests on 
photocells and sensitive edges, every six months. Keep glass 
panels constantly clean (use a slightly water-moistened cloth; 
do not use solvents or any other chemical products) • If the 
system requires repairs or modifi cations, release the operator 
and do not use it until safety conditions have been restored 
• Cut off the power supply before releasing the operator for 
manual openings. See instructions • Users are FORBIDDEN 
to carry out ANY ACTIONS THAT THEY HAVE NOT BEEN 
EXPRESSLY ASKED TO DO OR SO INDICATED in the manu-
als. Any repairs, modifi cations to the settings and extraor-
dinary maintenance MUST BE DONE BY THE TECHNICAL 
ASSISTANCE STAFF • On the periodic maintenance log, note 
down the checks you have done.

Special instructions and 

advice for all

• Avoid working near the hinges or moving mechanical parts 
• Stay clear of the gate’s area of operation when in motion • 
Do not resist the direction of movement of the gate; this may 
present a safety hazard • At all times be extremely careful 
about dangerous points that must be indicated by proper 
pictograms and/or black and yellow stripes • When using 
a selector or command in ‘maintained action’ mode, keep 
checking that there are no people in the area of operation of 
the moving parts. Do this until you release the command • 
The gate may move at any time without warning • Always cut 
the power when cleaning performing maintenance. 

Содержание PSEP0S00

Страница 1: ...SALOON SERIES INSTALLATION MANUAL PSEPOS00 PSEPSS00 SWING GATE TURNSTILE English EN 20EN...

Страница 2: ...pletely visible If missing ap ply a permanent label that shows the position of the release mechanism Before delivering to the client verify that the system is EN 12453 impact test standard compliant M...

Страница 3: ...THIS PAGE LEFT INTENTIONALLY BLANK THIS PAGE LEFT INTENTIONALLY BLANK...

Страница 4: ...built by CAME Cancelli Automatici S p A in compliance with the current safety legislation Bidirectional motorised swing gate made entirely of varnished AISI 304 Inox steel with removable upper cover...

Страница 5: ...p a The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH mm 4 4 Dimensi...

Страница 6: ...ersons exit 5 Typical applications Standard Sensor activated automatic opening with timed closing right hand column Double wing gate turnstile Sensor activated automatic opening with timed closing lef...

Страница 7: ...han 3 mm apart and power source isolation Set up proper tubing and conduits for the electrical cables to go through with enough protection from any mechanical damage Check that any connections within...

Страница 8: ...and securing the turnstile to the ground Depending on the transit opening measurements choose where to position the turnstile and any accessories Mark with a pencil the anchoring holes as shown in th...

Страница 9: ...lation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH Position the turnstile along the gussets and run any cable conduits...

Страница 10: ...s p a The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH Insert the wi...

Страница 11: ...and Hole Hole Power up the command board via the power supply unit Power supply unit 24DC 7 1 Cable types and sections N B If the cable length differs to that shown in the table determine cable sectio...

Страница 12: ...ively exceed 35W The de nable command and control functionalities are Clockwise action Counter clockwise action WARNING before doing any work inside the equipment cut off the power mains 8 1 General d...

Страница 13: ...obligation on CAME cancelli automatici s p a to notify users ENGLISH Connecting devices to the control panel Thrust meter 24V D C gearmotor Connecting complementary devices to the command panel Openi...

Страница 14: ...ometric device which constantly controls the motor thrust When the wing runs into an obstacle the sensor detects the thrust overload and inverts the direction of the wing s travel If the Dip switch is...

Страница 15: ...usceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH 9 4 Securing the cover and lid 1 Position the top cover and tighten the screws 2 Caref...

Страница 16: ...internal cabling check that cables are not disconnected or damaged Use hands to verify secure grounding of turnstile if not tightly anchored it could be dangerous Do not clean the turnstile with chem...

Страница 17: ...a The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH Set Dip switch 5...

Страница 18: ...li automatici s p a to notify users ENGLISH Shortcircuit terminals 22 23 the wing will move clockwise Keep terminals shorted until chosen endpoint C is reached Press P1 again and wait for con rmation...

Страница 19: ...08 2010 CAME cancelli automatici s p a The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to n...

Страница 20: ...e data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH The wing goes automat...

Страница 21: ...lation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH Shortcircuit terminals 22 23 the wing will move counter clockwise B...

Страница 22: ...er cylinder until the Ohm tester reads 5 00 Set the wing as shown in the picture insert the thrust gauge into its housing screw it down and plug in the connector into the socket on the board Setting t...

Страница 23: ...roducts are made with different materials The majority of these i e aluminium plastic iron electrical cables consist of solid urban waste They can be recycled at authorised recycling centres Other com...

Страница 24: ...ion Solutions Pvt Ltd Automation Solutions Pvt Ltd A 10 Green Park 110016 New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A 11345 NW 1...