background image

Pa

g.

 

1

4

14

  - M

an

u

al c

od

e: 

11

9

G

3

1

2

0

11

9

G

3

1

2

0

 ve

r.

 

0

.2

0.

2

  0

8

/2

0

10  © C

A

M

E c

an

ce

lli auto

m

ati

ci s.p.a. - T

h

e d

ata a

n

d i

nf

or

m

ati

on r

ep

orte

d i

n th

is i

n

sta

lla

tio

n m

an

u

al a

re s

u

sc

ep

tib

le to

 c

h

an

g

e at a

ny ti

m

e a

n

d w

ith

ou

t o

b

lig

ati

on o

n C

A

M

E c

an

ce

lli auto

m

ati

ci s.p.a. to n

otify u

se

rs.

ENGLISH

Do not allow children to play or loiter in the operating range of the turnstile. 
Keep command and control devices out of reach of children, to prevent the turnstile from being accidentally activated. 
Immediately suspend use of the turnstile if any anomalies are manifested.

Danger Hands could be crushedr

Danger voltage running through parts

Transit prohibited during operation.

 

 Important general safety instructions 

This product must be only used for its specific intended purpose. Any other use is wrongful and therefore dangerous. The manu-
facturer is not liable for any harm or damage caused by improper, wrongful or unreasonable use.

9 Safety instructions

 The periodic maintenance checks are the following:

 Check turnstile’s internal cabling, check that cables are not disconnected or damaged. 
Use hands to verify secure grounding of turnstile, if not tightly anchored it could be dangerous.

Do not clean the turnstile with chemical products that may damage the stainless steel, do not use abrasive substances 
or rags that may scratch the surface.

10.1 Periodic maintenance

DISFUNCTIONS

POSSIBLE CAUSES

CHECK AND REMEDIES

The turnstile release only to-
wards one direction

• Buttons 22-23 or 24-25 are pressed down

• Check connections

The turnstile remains locked

• Active STOP button

• Check validity of release command

10.2 Trouble shooting

10 Maintenance

10.3 Possible reprogramming of the end points

If you need to reprogram the turnstile’s end points (e.g. when setting a diff erent opening angle for the wing), follow the proce-
dure described below:

 IMPORTANT: before programming, carefully read all instructions and follow them in the order they are presented otherwi-

se you will not be able to program. Each time the P1 button is pressed, a sound should be emitted confi rming a command has 
been received. Wait for this sound signal, before pressing button again.
The programming procedure is fi nished when you hear a triple beep sound.

Содержание PSEP0S00

Страница 1: ...SALOON SERIES INSTALLATION MANUAL PSEPOS00 PSEPSS00 SWING GATE TURNSTILE English EN 20EN...

Страница 2: ...pletely visible If missing ap ply a permanent label that shows the position of the release mechanism Before delivering to the client verify that the system is EN 12453 impact test standard compliant M...

Страница 3: ...THIS PAGE LEFT INTENTIONALLY BLANK THIS PAGE LEFT INTENTIONALLY BLANK...

Страница 4: ...built by CAME Cancelli Automatici S p A in compliance with the current safety legislation Bidirectional motorised swing gate made entirely of varnished AISI 304 Inox steel with removable upper cover...

Страница 5: ...p a The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH mm 4 4 Dimensi...

Страница 6: ...ersons exit 5 Typical applications Standard Sensor activated automatic opening with timed closing right hand column Double wing gate turnstile Sensor activated automatic opening with timed closing lef...

Страница 7: ...han 3 mm apart and power source isolation Set up proper tubing and conduits for the electrical cables to go through with enough protection from any mechanical damage Check that any connections within...

Страница 8: ...and securing the turnstile to the ground Depending on the transit opening measurements choose where to position the turnstile and any accessories Mark with a pencil the anchoring holes as shown in th...

Страница 9: ...lation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH Position the turnstile along the gussets and run any cable conduits...

Страница 10: ...s p a The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH Insert the wi...

Страница 11: ...and Hole Hole Power up the command board via the power supply unit Power supply unit 24DC 7 1 Cable types and sections N B If the cable length differs to that shown in the table determine cable sectio...

Страница 12: ...ively exceed 35W The de nable command and control functionalities are Clockwise action Counter clockwise action WARNING before doing any work inside the equipment cut off the power mains 8 1 General d...

Страница 13: ...obligation on CAME cancelli automatici s p a to notify users ENGLISH Connecting devices to the control panel Thrust meter 24V D C gearmotor Connecting complementary devices to the command panel Openi...

Страница 14: ...ometric device which constantly controls the motor thrust When the wing runs into an obstacle the sensor detects the thrust overload and inverts the direction of the wing s travel If the Dip switch is...

Страница 15: ...usceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH 9 4 Securing the cover and lid 1 Position the top cover and tighten the screws 2 Caref...

Страница 16: ...internal cabling check that cables are not disconnected or damaged Use hands to verify secure grounding of turnstile if not tightly anchored it could be dangerous Do not clean the turnstile with chem...

Страница 17: ...a The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH Set Dip switch 5...

Страница 18: ...li automatici s p a to notify users ENGLISH Shortcircuit terminals 22 23 the wing will move clockwise Keep terminals shorted until chosen endpoint C is reached Press P1 again and wait for con rmation...

Страница 19: ...08 2010 CAME cancelli automatici s p a The data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to n...

Страница 20: ...e data and information reported in this installation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH The wing goes automat...

Страница 21: ...lation manual are susceptible to change at any time and without obligation on CAME cancelli automatici s p a to notify users ENGLISH Shortcircuit terminals 22 23 the wing will move counter clockwise B...

Страница 22: ...er cylinder until the Ohm tester reads 5 00 Set the wing as shown in the picture insert the thrust gauge into its housing screw it down and plug in the connector into the socket on the board Setting t...

Страница 23: ...roducts are made with different materials The majority of these i e aluminium plastic iron electrical cables consist of solid urban waste They can be recycled at authorised recycling centres Other com...

Страница 24: ...ion Solutions Pvt Ltd Automation Solutions Pvt Ltd A 10 Green Park 110016 New Delhi New Delhi 91 11 64640255 256 91 2678 3510 CAME Americas Automation Llc CAME Americas Automation Llc U S A 11345 NW 1...

Отзывы: