F9
Obstruction detection
with motor stopped
With the barrier closed, open, or after a total stop, the gearmotor stays idle if the safety devices,
that is, the photocells, detect an obstruction.
0
= Deactivated (
default
) /
1
= Activated
F10
State of barrier
notifi cation output
It signals the barrier's state The signal device is connected to contact 10-5.
0
= on with boom raised and moving (
default
) /
1
= it fl ashes intermittently each half second when
the boom is opening, and fl ashes intermittently each second when the boom is closing, and stays
on when the boom is raised, and stays off when the boom is lowered.
F11
Encoder
Managing slow-downs, obstruction detections and sensitivity.
0
= Activated (
default
) /
1
= Deactivated
F14
Sensor type
Setting the type of accessory for controlling the operator.
0
= command with transponder sensor or magnetic card reader /
1
= command with keypad
selector (
default
)
F15
Luminous cord
It signals the state of the barrier by using intermittent lights. Luminous cord connected onto 10-E6.
0
= Boom is moving (
default
) /
1
= Boom is moving and lowered.
F18
Additional light
Output for connecting the additional light onto 10-E1:
- fl ashing light, which fl ashes when the barrier is opening and closing;
- cycle, stays on from the moment the barrier starts opening until it is fully closed, including the
waiting time before the automatic closing.
- courtesy, stays on for a settable time of between 60 and 180 seconds. To set the time, see
function F25.
0
= Flashing light
(
default
) /
1
= Cycle /
2
= Courtesy
F19
Automatic Closing
Time
The automatic-closing wait starts when the opening limit switch point is reached and can be set to
between 1 and 180 seconds. The automatic closing does not activate if any of the safety devices
trigger when an obstruction is detected, or after a total stop, or during a power outage.
0
= Deactivated (
default
) /
1
= 1 second /... /
180
= 180 seconds
F21
Pre-fl ashing time
Adjusting the pre-fl ashing time of the fl ashing light connected to 10-E1 before each maneuver. The
fl ashing time is adjustable from one to ten seconds.
0
= Deactivated (
default
) /
1
= 1 second /... /
10
= 10 seconds
F22
Operating time
Motor's operating time, when opening and closing. It can be set to between 5 and 120 seconds.
5
= 5 seconds /... /
120
= 120 seconds (
default
)
F25
Courtesy light time
Additional light (courtesy), stays lit for the necessary time while the barrier is opening and closing.
It can be set to between 60 and 180 seconds.
60
= 60 seconds /... /
180
= 180 seconds (
default
)
F28
Speed of opening
maneuver
Setting the barrier's opening speed, calculated as a percentage.
Warning!
The speed parameter fi elds vary depending on the type of boom:
- for booms of 2 m to 4 m with jointed boom, set the speed percentage to between 70 and 100;
- for booms of 6 m and 8 m, set the speed percentage to between 80 and 100.
70
= 70% of the maximum speed /… /
100
= 100% of the maximum speed
F29
Speed of closing
maneuver
Setting the barrier's closing speed, calculated as a percentage.
Warning!
The speed parameter fi elds vary depending on the type of boom:
- for jointed booms of 2 m to 4 m, set the speed percentage to between 70 and 100;
- for booms of 6 m and 8 m, set the speed percentage to between 80 and 100.
70
= 70% of the maximum speed /… /
100
= 100% of the maximum speed
F30
Opening slow-down
speed
Setting the barrier's opening slow-down speed, calculated as a percentage.
Warning!
The speed parameter fi elds vary depending on the type of boom:
- for jointed booms of 2 m, set the slow-down speed percentage to between 20 and 40;
- for booms of 4 m, set the slow-down speed percentage to between 20 and 35.
- for booms of 6 m and 8 m, set the slow-down speed percentage to between 15 and 40.
15
= 15% of the maximum speed /… /
40
= 40% of the maximum speed