Display
The ESC button is for:
- exiting menus;
- cancelling changes.
The < > keys are for:
- moving from one item to another;
- increasing or decreasing values.
The ENTER key is for:
- entering menus;
- confirming or memorizing set values.
PROGRAMMING
DESCRIPTION OF THE PROGRAMMING COMMANDS
To enter the menu, keep the ENTER button pressed
for at least one second.
To exit the menu, wait 10 seconds or press ESC.
FUNCTIONS MENU
⚠
When programming, the operator needs to be in stop mode.
F1
Total stop [1-2]
NC input - Barrier stops while excluding any automatic closing; to resume movement, use the
control device. Fit the safety device onto (1-2), if unused, select 0.
0
= Deactivated (
default
) /
1
= Activated
F2
Input [2-CX]
NC Input - For associating: C1 = reopening during closing for photocells, C4 = obstruction wait, C5
= immediate closing, C9 = immediate closing with obstruction wait when closing.
0
= Deactivated (
default
) /
1
=C1 /
4
=C4 /
5
=C5 /
9
=C9
F3
Input [2-CY]
NC Input - For associating: C1 = reopening during closing for photocells, C4 = obstruction wait, C5
= immediate closing, C9 = immediate closing with obstruction wait when closing.
0
= Deactivated (
default
) /
1
=C1 /
4
=C4 /
5
=C5 /
9
=C9
F5
Safety test
After every opening or closing command, the board will check whether the photocells are working
properly.
0
= Deactivated (
default
) /
1
=CX /
2
=CY /
4
=CX+CY
F6
Maintained action
The barrier opens and closes by keeping a button pressed. Opening button on contact 2-3 and
closing button on contact 2-4. All other control devices, even radio-based ones, are excluded.
0
= Deactivated (
default
) /
1
= Activated