M2
M1
M2
M1
2
a
i
-
-
-
o p 2
o p i
p.
2
1
21
- M
an
u
al
c
od
e:
F
A
0
0
0
9
5
-E
N
F
A
00095
-E
N
v.
4 - 0
8
/2
0
17 - © C
am
e S
.p.
A
. T
h
e c
onte
nts of th
is
m
an
u
al
m
ay b
e c
h
an
g
ed at a
ny ti
m
e w
ith
ou
t p
rio
r n
oti
ce
.
Motors test
Select A 2.
Press ENTER to confi rm.
Select 1 and press ENTER to confi rm the motors test procedure.
The following [---] characters will be displayed while waiting for a
command.
Keep pressed the > key and check whether the M2 second
gearmotor's leaf performs an opening maneuver.
If the leaf performs an opening maneuver, invert the motor's
phases.
Perform the same procedure using the < arrow key to check the M1
fi rst gearmotor's leaf.
If the leaf performs an opening maneuver, invert the motor's
phases.
U 1 Entering a user
1 = Step-step command (open-close) / 2 = Sequential command (open-stop-close-stop) / 3 = Only open
command / 4 = Partial command
Entering up to up to a 25 users maximum and associating to each one a function chosen among the existing ones. This must be done via
transmitter or other control device (see "ENTERING USERS WITH ASSOCIATED COMMAND paragraph).
U 2 Deleting a user
Deleting a single user
U 3 Deleting users
0 = Deactivated / 1 = Deleting all users
Deleting all users.
A 1 Motor type
1 = SWN20 - SWN25 (
default
) / 2 = FA7024CB
Selecting the gearmotor used on the system.
A 2 Motors test
0 = Disable / 1 = Activate
Test for checking the gearmotors' proper rotating directions (see the MOTORS TEST paragraph).
A 3 Travel calibration
0 = Disable / 1 = Activate
Automatic calibration of the gate-leaf run (see the TRAVEL CALIBRATION paragraph).
This function appears only is the Encoder function is activated.
A 4 Resetting parameters
0 = Disable / 1 = Activate
Warning! The default settings are restored and the travel calibration deleted.
A 5 Counting maneuvers
0 = Number of maneuvers made / 1 = Deleting all maneuvers
For viewing the number of maneuvers completed or for deleting them (001 = 100 maneuvers; 010 = 1,000 maneuvers; 100 = 10,000
maneuvers; 999 = 99,900 maneuvers; CSI = maintenance job)
H 1 Version
View the fi rmware version.
Содержание FAST 70
Страница 33: ...Operator for swing gates FA7024CB INSTALLATION MANUAL EN English FA00095 EN...
Страница 65: ...Automatisme pour portails battants FA7024CB MANUEL D INSTALLATION FR Fran ais FA00095 FR...
Страница 96: ...CAME S p A Via Martiri Della Libert 15 31030 Dosson di Casier Treviso Italy tel 39 0422 4940 fax 39 0422 4941...
Страница 97: ...A FA7024CB RU FA00095 RU...
Страница 98: ...2 2 FA00095 RU FA00095 RU 4 4 08 2017 Came S p A CAME S P A 2 5 20 1 85 1 5 EN 12453 8...
Страница 100: ...4 4 FA00095 RU FA00095 RU 4 4 08 2017 Came S p A 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 10 11 12...
Страница 103: ...7 7 FA00095 RU FA00095 RU 4 4 08 2017 Came S p A...
Страница 104: ...UNI 6593 14 UNI 5739 M10x14 12 UNI 6593 6 UNI 5739 M6x10 8 8 FA00095 RU FA00095 RU 4 4 08 2017 Came S p A...
Страница 105: ...UNI 5739 M6x10 UNI 6593 6 UNI 6592 12 12 9 9 FA00095 RU FA00095 RU 4 4 08 2017 Came S p A...
Страница 106: ...10 10 FA00095 RU FA00095 RU 4 4 08 2017 Came S p A...
Страница 118: ...M2 M1 M2 M1 M2 M1 M2 M1 3 a i C l i o p i c l 2 o p 2 22 22 FA00095 RU FA00095 RU 4 4 08 2017 Came S p A 3 ENTER 1 ENTER...
Страница 121: ...25 25 FA00095 RU FA00095 RU 4 4 08 2017 Came S p A...
Страница 123: ...27 27 FA00095 RU FA00095 RU 4 4 08 2017 Came S p A...
Страница 125: ...29 29 FA00095 RU FA00095 RU 4 4 08 2017 Came S p A 6...
Страница 127: ...31 31 FA00095 RU FA00095 RU 4 4 08 2017 Came S p A CAME S p A UNI EN ISO 14001...