p.
15
- Manual
FA01346-EN
- 05/2019 - © C
AME S.p.A. - The cont
ents of this manual may change, at any time, and without notice. - Original instructions
Input voltage
Make sure the mains power supply is disconnected during all installation procedures.
Before working on the control panel, cut off the mains power supply.
Operator with 400 V AC three-phase power supply
The operator is designed to be powered at 400 V AC three-phase.
R
T
S
N
Operator with 230 V AC three-phase power supply
Remove the control panel, the panel support and the protection cover of the gearmotor connections.
Change the gearmotor contacts connections.
Reposition and fasten the control panel to the gearmotor.
Move the short-circuit jumper from the 400 V terminal to the 230 V terminal.
R
T
S
N
Input voltage
Make sure the mains power supply is disconnected during all installation procedures.
Before working on the control panel, cut off the mains power supply.
Connection to the power grid (230/400 V AC - three-phase - 50/60 Hz)