p.
17
- Manual
FA01346-EN
- 05/2019 - © C
AME S.p.A. - The cont
ents of this manual may change, at any time, and without notice. - Original instructions
Command and control devices
1
STOP button (NC contact)
It stops the gate and excludes the automatic closing. Use a control device to resume movement.
If the contact is not used, it must be deactivated during the programming.
2
Control device (NO contact)
OPEN ONLY function - For opening only.
3
Control device (NO contact)
PARTIAL OPENING function - It allows the gate partial opening.
4
Control device (NO contact)
CLOSE ONLY function - For closing only.
5
Control device (NO contact)
OPEN-CLOSE (step-step) or OPEN-STOP-CLOSE-STOP (sequential) function
6
Antenna with RG58 cable
2
3
4
5
1
6
Safety devices
During programming, configure the type of action that must be performed by the device connected to the input.
Connect the safety devices to the C1 and/or CX inputs.
If contacts C1 and/or CX are not used they must be deactivated during programming.
DELTA photocells
Standard connection
DELTA photocells
Connection with safety test
+
10
-
11 NO C NC
+
10
-
11
RX
TX
+
10
-
11 NO C NC
+
10
-
11
DELTA Collegamento test sicurezza
RX
TX