P
age
25
- Manual
FA01795-EN
- 03/2022 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Opening direction
Set gate-opening direction.
Configuration >
Motor settings
Opening direction
To the left (Default)
To the right
Encoder
Use the encoder input from the motor.
Configuration >
Motor settings
Encoder
Activated (Default)
Off
Motor test
Check correct gate-leaf opening direction.
If the buttons do not execute the commands correctly, invert the gate-opening direction using the [Opening direction] function.
The gate will move at reduced speed.
Configuration >
Motor settings
Motor test
The > button moves the gate to the right
The < button moves the gate to the left
Travel calibration
Start the travel self-learning.
Configuration >
Motor settings
Travel calibration
Motor type
Set the type of gearmotor installed.
Configuration >
Motor settings
Motor type
BXV04AGE
BXV06AGE
BXV10AGE
Opening speed
Set the opening speed (percentage of maximum speed).
Configuration >
Gate travel settings
Opening speed
30% to 100% (Default 100%)
Closing speed
Set the closing speed (percentage of maximum speed).
Configuration >
Gate travel settings
Closing speed
30% to 100% (Default 100%)
Opening slowdown speed
Set the slowdown speed during opening (as a percentage of the maximum speed).
If the slowdown speed is incorrectly set to a value higher than the opening speed by mistake, the parameter is corrected.
Configuration >
Gate travel settings
Opening slowdown speed
5% to 60% (Default 50%)