riginal instructions
Closing slowdown speed
Set the slowdown speed during closing (as a percentage of the maximum speed).
If the slowdown speed is incorrectly set to a value higher than the closing speed by mistake, the parameter is corrected.
Configuration >
Gate travel settings
Closing slowdown speed
5% to 60% (Default 50%)
Travel AST control
Adjust the obstruction detection sensitivity during the gate travel in percentage terms.
Configuration >
Gate travel settings
Travel AST control
Deactivated (Default)
Maximum thrust and low obstruction sensitivity.
Minimum
Average
Maximum*
*
Minimum thrust and high obstruction sensitivity.
Customised
The personalised values to be used are expressed as a percentage:
- from 10% (minimum thrust and high obstruction sensitivity)
- to 100% (maximum thrust and low obstruction sensitivity)
Slowdown AST control
Adjust the obstruction detection sensitivity during slowdown in percentage terms.
Configuration >
Gate travel settings
Slowdown AST control
Deactivated (Default)
Maximum thrust and low obstruction sensitivity.
Minimum
Average
Maximum*
*
Minimum thrust and high obstruction sensitivity.
Customised
The personalised values to be used are expressed as a percentage:
- from 10% (minimum thrust and high obstruction sensitivity)
- to 100% (maximum thrust and low obstruction sensitivity)
Soft start
Set a slowdown of a few seconds after each opening and closing command.
Configuration >
Gate travel settings
Soft start
Deactivated (Default)
On
Adjusting the partial opening
Set the gate’s partial-opening percentage.
Configuration >
Gate travel settings
Part. open point
10% to 100% (20% Default)