Signal maintenance
Set the colour of the flash on enabled BUS devices (flashing beacons and selectors) when maintenance is necessary. With the function activated, these devices will
signal that maintenance needs to be carried out at the start of each manoeuvre.
Maintenance must be configured [Function Configure Maintenance].
The function only appears if there is a BUS flashing beacon or a BUS selector connected.
Configuration >
Manage lights >
BUS device lights
Signal maintenance
Deactivated (Default)
White
Yellow
Orange
Red
Purple
Blue
Light blue
Green
RSE communication
Configure the function performed by the board inserted in connector RSE1.
If an RSE card – configured for paired connections – is plugged into the RSE_1 connector, use the RSE_2 connector for remote connection (CRP). In this
case, a CAME KEY cannot be connected.
Configuration >
RSE communication
RSE1
CRP (Default)
Paired
CRP address
Assign a unique identification code (CRP address) to the control board.
The function is used where there are multiple operators connected to the same communication BUS using the CRP protocol.
Configuration >
RSE communication
CRP address
1 to 254 (Default 1)
RSE1 speed
Set the remote connection system communication speed on the RSE1 port.
Configuration >
RSE communication
RSE1 speed
2400 bps
4800 bps
9600 bps
14400 bps
19200 bps
38400 bps (Default)
57600 bps
115200 bps
RSE2 speed
Set the remote connection system communication speed on the RSE2 port.
Configuration >
RSE communication
RSE2 speed
2400 bps
4800 bps
9600 bps
14400 bps
19200 bps
38400 bps (Default)
57600 bps
115200 bps