Page
39
- Manual
FA01798-EN
- 01/2023 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
PAIRED OPERATION
Two connected operators are controlled with one command.
Electrical connections
Connect the two electronic boards with a UTP CAT 5 cable.
Insert an RSE card into both control boards.
Connect up the electrics for the devices and accessories.
The devices and accessories must be connected to the control board which will be set as the MASTER.
For information on connecting the electrics for the devices and accessories, please see the “ELECTRICAL CONNECTIONS” section.
UTP CAT 5 (max 1000 m)
RSE
A B GND
A B GND
RSE
A B GND
A B GND
Programming
All programming operations described below must be performed only on the control board set as the MASTER.
Select the [Paired] system type when following the guided procedure, or configure the RSE_1 port to [Paired] mode.
After programming the MASTER operator in [Paired], the second operator automatically becomes SLAVE.
Saving users
All save user operations must be performed only on the control board set as the MASTER.
Operating modes
1
PARTIAL OPENING command
2
STEP-BY-STEP command
MASTER
SLAVE
MASTER
SLAVE
2
1