P
age
13
- Manual
FA01359-EN
- 03/2021 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Signalling devices
During programming, confi gure the type of action that must be performed by the device connected to the output.
1
Flashing beacon
It fl ashes when the operator opens and closes.
See function [F18] additional light.
2
Additional light
It increases the light in the manoeuvring area.
See function [F18] additional light.
3
Operator status warning light
It notifi es the user of the operator status.
See function [F10] open warning light or enable electric lock.
4
Connection for the 12 V AC electric lock - 15 W max.
See function [F10] open warning light or enable electric lock.
Replace the 2 A accessories fuse with a 3.15 A fuse.
5
Resistance 6.8 Ω - 7 W