Command 2-7
Associate a command with the device connected to 2-7.
F7
Command 2-7
0 = Step-by-step (default)
1 = Sequential
2 = Open
3 = Close
Command 2-3P
Associate a command to the connected device on 2-3P.
F8
Command 2-3P
0 = Pedestrian opening (Default)
Complete opening of M2 only.
1 = Partial opening
Partial opening of M2 only.
The M2 opening degree is set
as a percentage, with function [F36]
Partial opening adjustment.
2 = Open
Obstruction detection with motor idle
With the function active, the gate remains idle if the safety devices detect an obstacle. The function is active when the gate is
closed, open or after a complete stop.
F9
Obstruction detection with motor
idle
OFF (Default)
ON
Open warning light or enable electric lock
It signals the gate status or enables the electric lock. Device connected the 10-5 output.
F10
Open warning light or enable
electric lock
0 = Warning light on (default) - The
warning light stays on when the gate is
moving or open.
1 = Warning light fl ashing - The
warning light fl ashes every half second
when the gate is opening and stays
on when the gate is open. The light
fl ashes every second when the gate is
closing, and remains off when the gate
is closed.
2 = The output enables an electric lock.
Encoder
Manage operator slowdowns, obstacle detection and sensitivity.
F11
Encoder
ON (Default)
OFF