background image

Page 

15

 - Manual 

FA01561-EN

  - 02/2023 - © C

AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T

ranslation of the o

riginal instructions

OUTWARDS OPENING

Deciding where to fasten the brackets

Close the gate manually.
First determine where the gate bracket needs to be positioned, then where the post bracket needs to be positioned.

 Respect the values indicated in the table.

A

 Additional bracket (not included)

1

2

3

A

B

E

A

5

60

A

ATS30DGS

ATS30DGR

ATS30DGM

Gate-leaf opening (°)

A

B

E

90°

150

150

910

ATS50DGS

ATS50DGM

Gate-leaf opening (°)

A

B

E

90°

200

200

1030

Содержание ATS50DGM

Страница 1: ...Swing gate gearmotor ATS30DGS ATS50DGS ATS30DGR ATS30DGM ATS50DGM INSTALLATION MANUAL FA01561 EN EN English...

Страница 2: ...Page 2 Manual FA01561 EN 02 2023 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions 1 2 3 1 2 3 4...

Страница 3: ...unauthorised personnel from entering especially minors In case of manual handling have one person for every 20 kg that needs hoisting for non manual handling use proper hoisting equipment in safe con...

Страница 4: ...trategies Simply follow these brief disposal guidelines DISPOSING OF THE PACKAGING The packaging materials cardboard plastic etc can be disposed of easily as solid urban waste separated for recycling...

Страница 5: ...ith encoder for swing gates with Max C up to 200 mm with leaf up to 5 m and 400 kg Grey RAL7024 801MP 0110 ATS30DGR Irreversible telescopic gearmotor 24 V with encoder for swing gates with max C 200 m...

Страница 6: ...otor 1 Gate bracket 2 Door to access the end of travel adjustment screws 3 Door to access the release mechanism 4 Sheath connector 5 Pillar bracket 6 Release key 7 Release cord 8 Cutting hazard labels...

Страница 7: ...keep it at room temperature where it has previously been stored or transported at a very high or very low temperature The average product life specified should be understood purely as an indicative e...

Страница 8: ...for fitting the operator and accessories varies depending on the area where it is installed It is up to the installer to find the most suitable solution The drawings refer to a gearmotor installed on...

Страница 9: ...or 120 First determine where the gate bracket needs to be positioned then where the post bracket needs to be positioned Respect the values indicated in the table A C B 60 60 E F 5 ATS30DGS ATS30DGR AT...

Страница 10: ...without notice Translation of the original instructions Fastening the brackets Secure the post bracket with plugs and screws The holes on the bracket fixing plate allow you to vary the opening angle o...

Страница 11: ...hanged at any time and without notice Translation of the original instructions Fastening the gearmotor Lubricate all moving parts on the operator A The self locking nut must be loosely tightened so as...

Страница 12: ...ICAL CONNECTIONS Before working on the control panel disconnect the mains power supply and remove the batteries if any Remove the protective cover to access the terminal block A Control panel B Gearmo...

Страница 13: ...orm these operations on both gearmotors Release the gearmotor Manually open the leaf to the desired point Disconnect the 9 pole terminal board Connect the multimeter set to check continuity to the Ra...

Страница 14: ...d on the multimeter Turn the shaft C ANTICLOCKWISE to determine the closing travel end point until the Rc Rc contact opens and the multimeter stops buzzing If you want to decrease the closing angle th...

Страница 15: ...where to fasten the brackets Close the gate manually First determine where the gate bracket needs to be positioned then where the post bracket needs to be positioned Respect the values indicated in th...

Страница 16: ...ical connections Before working on the control panel disconnect the mains power supply and remove the batteries if any Remove the protective cover to access the terminal block A Control panel B Gearmo...

Страница 17: ...l range To move the microswitch 10 mm in either direction turn the rod 20 times A C Determining the opening end of travel points Perform these operations on both gearmotors Release the gearmotor Manua...

Страница 18: ...t the 9 pole terminal board Connect the multimeter set to check continuity to the Ra Ra terminals NC contact a buzzer will sound on the multimeter Turn the shaft A CLOCKWISE to determine the closing t...

Страница 19: ...ance If the system is not used for long periods of time e g for installations at sites with seasonal closures disconnect the power supply When the power supply is reconnected check the system is worki...

Страница 20: ...AME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions CAME S p A Via Martiri della Libert 15 31030 Dosson di Casier Treviso Italy...

Отзывы: