Page
7
- Manual
FA01561-EN
- 02/2023 - © C
AME S.p.A. - The contents of this manual may be changed at any time and without notice. - T
ranslation of the o
riginal instructions
Usage limitations
MODELS
ATS30DGS
ATS50DGS
ATS30DGR
Gate-leaf length (m)
3
2,5
2
-
5
4
3
2,5
2
-
3
2,5
2
-
Leaf weight (kg)
400
600
800
400
500
600
800
1000
400
600
800
MODELS
ATS30DGM
ATS50DGM
Gate-leaf length (m)
3
2,5
2
-
5
4
3
2,5
2
-
Leaf weight (kg)
400
600
800
400
500
600
800
1000
For leaves longer than 2.5 m, install an electric lock.
Technical data
MODELS
ATS30DGS
ATS50DGS
ATS30DGR
ATS30DGM
ATS50DGM
Motor power supply (V)
24 DC
24 DC
24 DC
24 DC
24 DC
Power (W)
80
80
80
80
80
Current draw (A)
8 MAX
8 MAX
8 MAX
8 MAX
8 MAX
Operating temperature (°C)
-20 ÷ +55
-20 ÷ +55
-20 ÷ +55
-20 ÷ +55
-20 ÷ +55
Storage temperature (°C)*
-20 ÷ +70
-20 ÷ +70
-20 ÷ +70
-20 ÷ +70
-20 ÷ +70
Thrust (N)
400 ÷ 3000
400 ÷ 3000
400 ÷ 3000
400 ÷ 3000
400 ÷ 3000
Opening time at 90° (s)
15 ÷ 30
15 ÷ 30
15 ÷ 30
15 ÷ 30
15 ÷ 30
Cycles/hour
CONTINUOUS
OPERATION
CONTINUOUS
OPERATION
CONTINUOUS
OPERATION
CONTINUOUS
OPERATION
CONTINUOUS
OPERATION
Sound pressure level (dB A)
≤70
≤70
≤70
≤70
≤70
Protection rating (IP)
54
54
54
54
54
Insulation class
I
I
I
I
I
Reduction ratio (i)
28
28
28
28
28
Weight (kg)
7.5
8
7.5
7.5
8
Average life (cycles)**
120.000
120.000
120.000
120.000
120.000
(*) Before installing the product, keep it at room temperature where it has previously been stored or transported at a very high or very low temperature.
(**) The average product life specified should be understood purely as an indicative estimate. It applies to normal usage conditions and where the product has been
installed and maintained in compliance with the instructions provided in the CAME technical manual. The average product life is also affected, including significantly,
by other variables such as, but not limited to, climatic and environmental conditions. The average product life should not be confused with the product warranty.
Cable types and minimum thicknesses
Cable length (m)
up to 20
from 20 to 30
Motor with encoder power supply 24 V DC
4G x 1.5 mm²
4G x 2.5 mm²
When operating at 230 V and outdoors, use H05RN-F cables compliant with 60245 IEC 57 (IEC); when indoors, use H05VV-F cables compliant with 60227 IEC 53
(IEC). For power supplies up to 48 V, use FROR 20-22 II cables compliant with standard EN 50267-2-1 (CEI).
If the cable lengths differ from those specified in the table, define the cable cross-sections according to the actual power draw of the connected devices and in
line with regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, recalculate the values in the table according to the actual power draw and distances. For information on
connecting products not covered in this manual, please see the documentation accompanying the products themselves.