[Radio signal]
Shows the radio signal level (from 1 to 6) for each learnt siren. If the siren has not
yet been learnt, the radio signal is 0.
The value is shown on the second line of the display as follows:
WL[#-----] = Level 1 signal (low)
WL[###---] = Level 3 signal (medium)
WL[#####-] = Level 5 signal (high)
Siren
Radio signal
The alarm events occur when the status on one of the configured inputs changes.
[Show alarms]
(default: YES)
Enables or disables the alarm view.
The alarm events may be:
- N.C.
(Status): the alarm status is reset by the user on the device that generated
the alarm (e.g. magnetic contact);
- CI
(impulse): the alarm status is reset once the time set in the
[SETTINGS]/[T.RE-
STORE]
menu has lapsed (e.g. shutter contact, volumetric sensors, etc.)
.
To set the alarm events, see the remote device manual.
These events are reset when the alarm stops but remain visible in the
[ALARM
MEMORY]
. They are permanently deleted when the ON/OFF channel is next ena-
bled or by entering the user code and pressing one of the
buttons.
[Test]
Changes the status on the chosen channel to check it is working correctly.
[Polarity]
(default: ON/OFF = 12V - engaged, SIREN = 12V - alarm, OTHER
= normally closed)
Chooses the channel operating status. This choice depends on the operation of the
control unit the receiver is connected to.
Polarity
[Status]
(default: all enabled except the ON/OFF channel)
[ENABLED]
the channel signal changes according to the configuration of the as-
sociated devices.
[DISABLED]
the channel signal does not change.
Choose which channel to enable:
- OUTPUTS (1 to 8),
- TAMPER, SUPERVISION, BATTERY and JAMMING,
- ON/OFF,
- SIREN
Events
Show alarm memory
Test
Status
Wired IN/OUT
Содержание 846NC-0140
Страница 1: ...FA00772M04 RICEVITORE UNIVERSALE MANUALE DI CONFIGURAZIONE PXWRXU...
Страница 13: ...FA00772 EN CONFIGURATION MANUAL PXWRXU MULTI PURPOSE RECEIVER...
Страница 25: ...FA00772 FR MANUEL DE CONFIGURATION PXWRXU R CEPTEUR UNIVERSEL...
Страница 37: ...FA00772 RU PXWRXU...
Страница 38: ...2 FA00772 RU 1 05 2017 CAME S p A 123456 222222 32 8 1 8 123456 222222...
Страница 39: ...3 FA00772 RU 1 05 2017 CAME S p A 1 3 1 8 1 8 1 15 12 0 12 0 1 254...
Страница 40: ...4 FA00772 RU 1 05 2017 CAME S p A 24 1 3 1 8 1 15 1 8 12 0 12 0 10 90 1 60 1 254 1 254 1 254 0 254...
Страница 42: ...6 FA00772 RU 1 05 2017 CAME S p A 3 8 1 8 1 6 0 WL 1 WL 3 WL 5...
Страница 43: ...7 FA00772 RU 1 05 2017 CAME S p A S 1 6 0 WL 1 WL 3 WL 5...
Страница 44: ...8 FA00772 RU 1 05 2017 CAME S p A NC CI 12 12 1 8 1 6 0 WL 1 WL 3 WL 5...
Страница 45: ...9 FA00772 RU 1 05 2017 CAME S p A 20 5 60 10 90 10 30...
Страница 46: ...10 FA00772 RU 1 05 2017 CAME S p A 123456 222222 1 2 3 0 10...
Страница 47: ...11 FA00772 RU 1 05 2017 CAME S p A 2 2 10 90 1 60 123456...