User menu
Info menu
Motor test menu
[Add User]
Enter up to a maximum of 250 users and associate each one with a function chosen from the available options. Use the transmitter or
another command device to do this (see ENTERING A NEW USER).
[Mod. name]
C
hange the number or the user name.
[Mod. Code]
Change the code for a command associated with a user
.
[Related Func]
2-7
Open
2-3P
B1-B2
➡
Step-by-step command (open-close) or sequential command (open-stop-close-stop)
➡
Open command
➡
Pedestrian or partial command
➡
Output contact B1-B2
[Remove Usr]
Remove a user. Confirm with ENTER.
[Delete all Usr]
Delete all users. Confirm with ENTER.
[Backup data]
Save users and system settings in the memory roll. Confirm with ENTER.
[Restore backup]
Load the data saved in the memory roll onto the electronic circuit board.
If the boards have different versions, only the users can be loaded.
[Version]
View the software version.
[No. of Runs]
View the number of runs performed.
[Standby Msg]
View the initial standby message. To change the text, press ENTER. Use the ENTER key to move the cursor forward, ESC to move it
backwards and <> to select the letter or number. Confirm by pressing the ENTER key and holding for a few seconds.
[System Reset]
Restore to the original settings. Press the ENTER key to confirm.
[
<= M1 M2=>
]
Test to check the correct rotation direction of the gearmotors.
Press the < key and hold for a few seconds. Check that the M1 gate leaf opens. If the direction is wrong, invert the motor phases.
Press the > key and hold for a few seconds. Check that the M2 gate leaf opens. If the direction is wrong, invert the motor phases.
[USERS]
[TEST MOT]
[INFO]