 CV-603 MPROXBLE CONTROLLER / CV-603PS-K1 MPROXBLE CONTROLLER CABINET KIT 

INSTALLATION INSTRUCTIONS

Bill of material:

Camden Model#

Camden Model#

Item

Description

Quantity CV-603PS-K1

CV-603

1

Controller

1

CV-603 provided in kit

CV-603

2

DC Power Supply

1

60-69B002 - provided in kit

PS-13

3

Transformer

1

CX-TRP-4016 provided in kit

CX-TRP-4016

4

Door Strike, 12 VDC

2

CX-ED1079

CX-ED1079

5

Door Position Switch, a door latch 

monitor switch can be used, add 

suffix "L" to CX-ED1079

2

CX-MDA surface or CX-MDH recessed.

CX-MDA surface or CX-MDH recessed.

6

Proximity Card Reader, 125 KHz. 

Not required if transmitters are 

used.

2

CV-7400

CV-7400

7

Request to Exit Device

1

CM-RQE70 PIR sensor or CM-30E Push 

button.

CM-RQE70 PIR sensor or CM-30E Push 

button.

System Operation:

a)  The doors are normally locked and closed. The door position switch confirms when the doors are closed.
b)  A user presents a card credential in front of the card reader. The card reader’s red LED indicates it is powered. When the credential is 

within 2 inches, the reader will beep, and the controller red LED will pulse on 1 second to confirm the credential data was received. If the 
controller red LED blinks twice, the credential is being denied by the controller.

c)  If the credential is approved by the controller, the door strike will energize for the pre-set period duration. The door strike will energize 

for the full duration of the period until the door is opened and the door position changes state. As soon as the door is opened, the door 
strike shall turn off securing the door as soon as it closes.

d)  Users exiting the door, must be detected by the request to exit device; manually by a push switch or automatically using a PIR detector. 

Opening the door without a request to exit switch shall cause the controller to generate a door forced open alarm.

e)  Administrators shall use the app to control and configure the CV-603 controller using wireless Bluetooth. A steady on blue LED on the 

controller will confirm the connection.

Содержание CV-603

Страница 1: ...of relay outputs 2 Types of relay outputs Timed 1 180 seconds Momentary bi stable latch Contact rating 30VDC 1 Amp Operating Temperature 4 F to 131 F 20 C to 55 C DIN rail mount Yes IP ratings IP 20...

Страница 2: ...Request to Exit PIR REX Detector Door Strike 12 VDC Wire Antenna AC AC Transformer DC Output AC DC 12V 6V BATT BATT Battery Leads ve ve Connect positive wire to colored wire representing the preferre...

Страница 3: ...twice the credential is being denied by the controller c If the credential is approved by the controller the door strike will energize for the pre set period duration The door strike will energize for...

Страница 4: ...rmer 16VAC 40 VA Card Reader AC to DC Power Supply Wire Antenna AC AC Transformer DC Output AC DC 12V 6V BATT BATT Battery Leads Cathode mark Diode Can be replaced with a MOV D1 grey orange Door Statu...

Страница 5: ...d credential in front of the card reader The card reader s red LED indicates it is powered When the credential is within 2 inches the reader will beep and the controller red LED will pulse on 1 second...

Страница 6: ...er CV 603 Transformer 16VAC 40 VA Card Reader AC to DC Power Supply Door Strike 12 VDC Wire Antenna AC AC Transformer DC Output AC DC 12V 6V BATT BATT Battery Leads 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15...

Страница 7: ...Cx 12 PLUS module The door operator will trigger to operate after the door strike has been energized Once the pre set periods have expired the door ope rator and strike shall de energize from the Cx 1...

Страница 8: ...N INSTRUCTIONS Gate Operator Card Reader Loop Detector Loop Detector Card Reader Gate Operator Power Supply 12 VDC GATE 1 GATE 2 TWO VEHICLE GATES ANTI PASSBACK Antenna 12 V GND Data 0 Data 1 Data 1 D...

Страница 9: ...ops in front of gate A sensor or loop detector will validate the position of the vehicle and enable both the card reader and receiver If the device wired to the VAL1 or VAL2 terminals do not detect th...

Страница 10: ...2 Take t holes from over the sn nuts onto t place 3 Push snaptrack hook onto BLE Base and Dinrail ASSEMBLY 1 Take the bottom of the BLE base and hook it onto the bottom of the DIN rail Then take the t...

Страница 11: ...Page 11 of 20 CV 603 MPROXBLE CONTROLLER CV 603PS K1 MPROXBLE CONTROLLER CABINET KIT INSTALLATION INSTRUCTIONS 41 8 105mm 2 3 4 70mm 1 4 5mm Drill 1 4 for screw 4 places 7 CV 603 BLE TEMPLATE...

Страница 12: ......

Страница 13: ...onals perform maintenance at the times and intervals required by the installer by the manufacturer and by current law All installation maintenance repair and cleaning operations must be documented The...

Страница 14: ...d Logo used for app 2 Open the app and click on UPDATE LIST icon a A default name for your controller will appear The title will state uninitialized 3 Tap on the default name and the home page will ap...

Страница 15: ...it Wiegand cards 6 Scheduling A pop up message will appear Do you want to configure a schedule now Click Yes to proceed to the Time table a You can rename the default name STANDARD to M F as an exampl...

Страница 16: ...you added more schedules you can select the schedule previously defined Lock and unlock Schedule Select one of the predefined schedules Select one of the predefined schedules Select one of the predef...

Страница 17: ...an alarm condition will occur Once you have made the selections click on the VALIDATE icon A pop up alert message will appear to confirm your settings have been saved Click ok to close Alarm Output R...

Страница 18: ...each Wiegand card number manually or auto enroll the ID number using the ID READ icon NOTE It is recommended that you use card credentials with the same facility code number you entered on Central Set...

Страница 19: ...elections turned on User management Backup and History to perform their daily tasks To manually reset alarms relay commands will need to be selected ANTI PASS BACK FEATURE MProxBLE uses hard anti pass...

Страница 20: ...6 152 7mm 9 5 8 243 9mm 7 7 8 200 2mm 11 1 8 281 4mm CV 603 MPROXBLE CONTROLLER CV 603PS K1 MPROXBLE CONTROLLER CABINET KIT I NS TAL LATI ON INST RUCTI ONS...