![Camco VORTEX 3 QUADRO Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/camco/vortex-3-quadro/vortex-3-quadro_user-manual_486578015.webp)
3 INST
ALL
ATION
+
ch A(C)
ch B(D)
1+
2+
Input
Channel A(C)
Z
≥
8
Ω
Input
Channel D
Input
Channel C
Input
Channel B
Input
Channel A
3
1
2
1
3
2
3
1
2
3
1
2
To Ch. D
input stage
To Ch. C
input stage
To Ch. B
input stage
To Ch. A
input stage
Input
Ground
Lift
Input Ground Lift in position:
grounded
USER MANUAL
VORTEX 3 QUADRO
P.14
USER MANUAL
VORTEX 3 QUADRO
P.15
3.8.3 Mono-Bridge
One-channel mono bridged operation.
The second channel processes the same input signal, but with reversed phase.
The (single) load is connected between the two positive channel outputs
(1+/2+) using a suitable connected SPEAKON connector. While the total output
of the amplifier remains the same, both the available output voltage and the
minimum impedance that can be connected are doubled, as compared with
stereo operation. Only Channel A(C)-Input is active – turn the volume on
Channel B(D) down to zero.
WARNING!
In Mono-Bidge mode RMS output voltages are as high as 230 V. Wiring
to the speaker loads must conform to NEC Class 3 safety standards or its
equivalent that meets all national and local electric codes.
All customer specific cables may only be manufactured by qualified
suppliers/personnel. All cabeling or rewiring work must be carried out by
qualified personnel.
3.9 Wiring
3.9.1 XLR Connection
XLR: Pin 1 Ground (or lifted via 15 Ohm resistor)
Pin 2 Hot
Pin 3 Cold
Always use symmetrical (balanced) shielded cable to connect the amplifier.
Содержание VORTEX 3 QUADRO